Improvement of the methods for skin mechanical properties evaluation through correlation between different techniques and factor analysis

Title
Improvement of the methods for skin mechanical properties evaluation through correlation between different techniques and factor analysis
Type
Article in International Scientific Journal
Year
2013
Authors
neto, p
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
ferreira, m
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
bahia, f
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
costa, p
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 19
Pages: 405-416
ISSN: 0909-752X
Publisher: Wiley-Blackwell
Other information
Authenticus ID: P-006-6DT
Abstract (EN): BackgroundIn the past decades, many instruments have been developed to measure skin elasticity and firmness. The offer is extensive and is constantly increasing, becoming difficult to decide which equipment and mechanical property measurement are better to portrait the desired characteristics. The aim of this study was to compare and correlate parameters assessed with different probes, based on different methodologies, to understand which probe characterizes each skin elasticity property. MethodsMeasurements were performed in the abdomen region of 34 female volunteers, with three different probes: Cutometer((R)) SEM575, Reviscometer((R)) RVM600 and Frictiometer((R)) FR700. Statistical data analysis was performed by Factor Analysis on IBM SPSS Statistics 17.0. ResultsFrictiometer((R)) and Reviscometer((R)) measurements showed significant correlations with Cutometer's Uf, Ua, Ur and Ue parameters. Ue was strongly and significantly correlated to Uf and Ur. Ua was strongly and significantly correlated with Ur, Uf and Ue. Reviscometer((R)) measurements were similar along the same axis, and measurements performed in a specific direction are significantly correlated with age. ConclusionA simpler and faster methodology for the complete assessment of elasticity and firmness of human skin is possible, in alternative to elaborate and time consuming methods, involving several equipments and parameters. The simpler methodology does not reduce the information obtained about the skin properties.
Language: English
Type (Professor's evaluation): Scientific
Contact: marta.ferreira@inovapotek.com
No. of pages: 12
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The role of AI classifiers in skin cancer images (2019)
Article in International Scientific Journal
Carolina Magalhães; Joaquim Mendes; Ricardo Vardasca
Recent use of medical infrared thermography in skin neoplasms (2018)
Article in International Scientific Journal
C. Magalhães; Ricardo Vardasca; Joaquim Mendes
Efficacy of anti-wrinkle products in skin surface appearance: a comparative study using non-invasive methods (2010)
Article in International Scientific Journal
ferreira, mr; costa, pc; bahia, fm
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-10 at 15:53:45 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book