Sample introduction in multi-syringe flow injection systems: comparison between time-based and volume-based strategies

Title
Sample introduction in multi-syringe flow injection systems: comparison between time-based and volume-based strategies
Type
Article in International Scientific Journal
Year
2005
Authors
Segundo, MA
(Author)
REIT
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Oliveira, HM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Almeida, MIGS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rangel, AOSS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Journal
Vol. 537
Pages: 207-214
ISSN: 0003-2670
Publisher: Elsevier
Indexing
Scientific classification
FOS: Natural sciences > Chemical sciences
CORDIS: Health sciences
Other information
Authenticus ID: P-000-3S2
Resumo (PT): In multi-syringe flow injection analysis (MSFIA), devices as selection, injection or commutation valves must be incorporated to the manifold to provide access to sample and standard solutions. Therefore, the definition of sample amount can be either volume or time-based. In the present work, four configurations for sample introduction (two for each approach) were tested in order to establish if the different strategies affect the analytical signal in MSFIA systems. The mean absorbance value from ten consecutive injections of a bromothymol blue solution obtained for the time-based strategy was lower than that provided by the volume-based approach as the exact volume delivered by each configuration was different from the “theoretical” volume. For time-based configurations, the exact volume delivered is 2–5% lower than the theoretical value while for volume-based configurations, the volume delivered was between 6 and 46% larger than the theoretical volume. Moreover, for time-based sampling, the order of steps in the analytical cycle was of utmost importance since any alteration in the flow direction affected the volume delivered in the subsequent step in the analytical cycle. The influence of the two sampling approaches was also evaluated in the MSFIA systems for the spectrophotometric determination of phenolic compounds and the potentiometric determination of chloride. There was no evidence that the use of either volume or time-based sampling would improve the analytical features of these determinations when real samples were tested. <br> <br> Keywords: Multi-syringe; Flow injection; Sampling strategy; Time-based sampling; Volume-based sampling <br> <a target="_blank" href="http://www.sciencedirect.com/science?_ob=ArticleURL&_udi=B6TF4-4FD0N2M-J&_user=2460038&_coverDate=04%2F29%2F2005&_rdoc=26&_fmt=high&_orig=browse&_srch=doc-info(%23toc%235216%232005%23994629998%23592300%23FLA%23display%23Volume)&_cdi=5216&_sort=d&_docanchor=&_ct=52&_acct=C000057398&_version=1&_urlVersion=0&_userid=2460038&md5=08725ccfc6150364d6ccbcd34ca2f556">Texto integral </a> <br> <br>
Abstract (EN): In multi-syringe flow injection analysis (MSFIA), devices as selection, injection or commutation valves must be incorporated to the manifold to provide access to sample and standard solutions. Therefore, the definition of sample amount can be either volume or time-based. In the present work, four configurations for sample introduction (two for each approach) were tested in order to establish if the different strategies affect the analytical signal in MSFIA systems. The mean absorbance value from ten consecutive injections of a bromothymol blue solution obtained for the time-based strategy was lower than that provided by the volume-based approach as the exact volume delivered by each configuration was different from the "theoretical" volume. For time-based configurations, the exact volume delivered is 2-5% lower than the theoretical value while for volume-based configurations, the volume delivered was between 6 and 46% larger than the theoretical volume. Moreover, for time-based sampling, the order of steps in the analytical cycle was of utmost importance since any alteration in the flow direction affected the volume delivered in the subsequent step in the analytical cycle. The influence of the two sampling approaches was also evaluated in the MSFIA systems for the spectrophotometric determination of phenolic compounds and the potentiometric determination of chloride. There was no evidence that the use of either volume or time-based sampling would improve the analytical features of these determinations when real samples were tested.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same scientific areas

Serine-based surfactants active against antibiotic-resistant bacteria (2018)
Poster in a National Conference
M. Luisa C Vale; Eduardo F Marques; Paula Gomes; Ana Rita Dias; Ricardo Ferraz; Sandra G. Silva; Cristina Prudêncio
Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Application of sequential injection analysis to pharmaceutical analysis (2006)
Another Publication in an International Scientific Journal
Pimenta, AM; Montenegro, MCBSM; Araujo, AN; Calatayud, JM

See all (159)

Of the same journal

Sequential injection analysis using electrochemical detection: A review (2005)
Another Publication in an International Scientific Journal
Perez Olmos, R; Soto, JC; Zarate, N; Araujo, AN; Montenegro, MCBSM
SEQUENTIAL FLOW-INJECTION DETERMINATIONS OF CALCIUM AND MAGNESIUM IN WATERS (1986)
Another Publication in an International Scientific Journal
ALONSO, J; BARTROLI, J; Lima, JLFC; MACHADO, AASC
Papers presented at the 10th International Conference on Flow Analysis Porto, Portugal, 3-8 September 2006 - Foreword (2007)
Another Publication in an International Scientific Journal
Purnendu Dasgupta; Jose L F C Lima; Lucia Saraiva; Marcela Segundo
Optical probes for detection and quantification of neutrophils' oxidative burst. A review (2009)
Another Publication in an International Scientific Journal
Marisa Freitas; Jose L F C Lima; Eduarda Fernandes
Nanoparticle-based assays in automated flow systems: A review (2015)
Another Publication in an International Scientific Journal
Marieta L C Passos; Paula C A G Pinto; Joao L M Santos; Lucia L M F S Saraiva; Andre R T S Araujo

See all (221)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-09 at 22:37:05 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book