An easy procedure for calibrating data acquisition systems using interleaving

Title
An easy procedure for calibrating data acquisition systems using interleaving
Type
Article in International Conference Proceedings Book
Year
2005
Authors
Clemencio, FMC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Loureiro, CFM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Correia, CMBA
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 680-684
Nuclear Science Symposium/Medical Imaging Conference
Fajardo, PR, OCT 23-29, 2005
Indexing
Other information
Authenticus ID: P-000-72D
Abstract (EN): Interleaving data acquisition channels is a well-known and interesting technique to achieve higher acquisition rates. However, to obtain the expected benefits, a careful look at the interleaving technique and to mismatches that can lead to unwanted harmonic distortion and noise is essential. In this paper we discuss the methods used to interleave existing high-speed, 250 MSPS 8-bit acquisition channels, and the results obtained. The methods presented allowed a good channel calibration in amplitude (amplitude mismatch under 0.1 Isb) and in time (time mismatch between acquisition channels in the ps range, under the specified maximum jitter for the ADC used). A dynamic, by software, amplitude level signal-dependent adjustment procedure is also suggested for signals with reach frequency content that can substantially improve the quality of the acquired signal when using interleaved channels. The techniques presented provide good results even in the presence of noise.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

An easy procedure for calibrating data acquisition systems using interleaving (2007)
Article in International Scientific Journal
Clemencio, FMC; Loureiro, CFM; Correia, CMBA
The design of a digital coincidence-detection trigger system for a RPC-based pet (2007)
Article in International Conference Proceedings Book
Clemencio, FMC; Loureiro, CFM; Correia, CMBA
A fundamental data acquisition saving block (2005)
Article in International Conference Proceedings Book
Loureiro, CFM; Martins, VMG; Clemencio, FMC; Correia, CMBA