Go to:
Logótipo
Você está em: Start > Publications > View > Local PWV and other hemodynamic parameters assessment: Validation of a new optical technique in an healthy population
Map of Premises
Principal
Publication

Local PWV and other hemodynamic parameters assessment: Validation of a new optical technique in an healthy population

Title
Local PWV and other hemodynamic parameters assessment: Validation of a new optical technique in an healthy population
Type
Article in International Conference Proceedings Book
Year
2013
Authors
Pereira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Santos, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Oliveira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vaz, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Almeida, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Cardoso, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Correia, C
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 61-69
International Conference on Bio-Inspired Systems and Signal Processing, BIOSIGNALS 2013
Barcelona, 11 February 2013 through 14 February 2013
Indexing
Other information
Authenticus ID: P-008-B2C
Abstract (EN): Presently the interest in non-invasive devices for monitoring the cardiovascular system has increased in importance, especially in the diagnosis of some pathologies. The proposed optical device reveals an attractive instrumental solution for local pulse wave velocity (PWV) assessment and other hemodynamic parameters analysis, such as Augmentation Index (AIx), Subendocardial Viability Ratio (SEVR), Maximum Rate of Pressure Change (dP/dtmax) and Ejection Time Index (ETI). These parameters allow a better knowledge on the cardiovascular condition and management of many disease states. Two studies were performed in order to validate this technology. Firstly, a comparative test between the optical system and a gold-standard in PWV assessment was carried out. Afterwards, a large study was performed in 131 young subjects to establish carotid PWV reference values as well as other hemodynamic parameters and to find correlations between these and the population characteristics. The results allowed the use of this new technique as a reliable method to determine these parameters. For the total of subjects values for carotid PWV vary between 3-7.69 m s-1 a clear correlation with age and smoking status was found out. The Aix varies between -6.15% and 11.46% and exhibit a negative correlation with heart, and dP/dtmax parameter shows a significant decrease with age.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Characterization of Optical System for Hemodynamic Multi-Parameter Assessment (2013)
Article in International Scientific Journal
Pereira, T; Santos, I; Oliveira, T; Vaz, P; Correia, T; Pereira, T; Santos, H; Pereira, H; Almeida, V; Cardoso, J; Correia, C
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-08 at 22:26:41 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book