Go to:
Logótipo
Você está em: Start > Publications > View > Impact of gaseous interferents on palladium expansion for hydrogen optical sensing: A time stability study
Map of Premises
Principal
Publication

Impact of gaseous interferents on palladium expansion for hydrogen optical sensing: A time stability study

Title
Impact of gaseous interferents on palladium expansion for hydrogen optical sensing: A time stability study
Type
Article in International Scientific Journal
Year
2024
Authors
Almeida, MAS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Journal
Vol. 170
ISSN: 0030-3992
Publisher: Elsevier
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00Z-6ZR
Abstract (EN): Continuous monitoring of hydrogen (H2) concentration is critical for safer use, which can be done using optical sensors. Palladium (Pd) is the most commonly used transducer material for this monitoring. This material absorbs H2 leading to an isotropic expansion. This process is reversible but is affected by the interaction with interferents, and the lifetime of Pd thin films is a recurring issue. Fiber Bragg Grating (FBG) sensors are used to follow the strain induced by H2 on Pd thin films. In this work, it is studied the stability of Pd-coated FBGs, protected with a thin Polytetrafluoroethylene (PTFE) layer, 10 years after their deposition to assess their viability to be used as H2 sensors for long periods of time. It was found that Pd coatings that were PTFE-protected after deposition had a longer lifetime than unprotected films, with the same sensitivities that they had immediately after their deposition, namely 23 and 10 pm/vol% for the sensors with 150 and 100 nm of Pd, respectively, and a saturation point around 2 kPa. Furthermore, the Pd expansion was analyzed in the presence of H2, nitrogen (N2), carbon dioxide (CO2), methane (CH4) and water vapor (H2O), finding that H2O is the main interferent. Finally, an exhaustive test for 90 h is also done to analyze the long-term stability of Pd films in dry and humid environments, with only the protected sensor maintaining the long-term response. As a result, this study emphasizes the importance of using protective polymeric layers in Pd films to achieve the five-year lifetime required for a real H2 monitoring application.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Preface (2019)
Another Publication in an International Scientific Journal
Lechuga, L; Raptis, I; Jorge, PAS; Cusano, A
Preface (2020)
Another Publication in an International Scientific Journal
Frazao, O; del Villar, I; Fabris, J; Gong, Y
[INVITED] New advances in fiber cavity ring-down technology (2016)
Another Publication in an International Scientific Journal
Susana Silva; Magalhaes, R; marques, mb; Frazao, O
Temperature independent refractive index measurement using a fiber Bragg grating on abrupt tapered tip (2018)
Article in International Scientific Journal
Gomes, AD; Silveira, B; Warren Smith, SC; Becker, M; Rothhardt, M; Frazao, O
On the Q-switched operation of Titanium:Sapphire lasers using a graphene-based saturable absorber mirror (2015)
Article in International Scientific Journal
Weigand, R; Pinto, T; Crespo, HM; Guerra, JM

See all (11)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-07 at 11:52:30 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book