Go to:
Logótipo
Você está em: Start > Publications > View > Changes in renal-mesenteric duplex ultrasound velocities after fenestrated and branched endovascular aortic aneurysm repair
Map of Premises
Principal
Publication

Changes in renal-mesenteric duplex ultrasound velocities after fenestrated and branched endovascular aortic aneurysm repair

Title
Changes in renal-mesenteric duplex ultrasound velocities after fenestrated and branched endovascular aortic aneurysm repair
Type
Article in International Scientific Journal
Year
2023
Authors
Sulzer T.A.L.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Macedo T.A.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Strissel N.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Hesley G.K.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lekah A.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Tallarita T.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Dias-Neto M
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Huang Y.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Tenorio E.R.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vacirca A.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mesnard T.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Baghbani-Oskouei A.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Savadi S.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
de Bruin J.L.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Verhagen H.J.M.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mendes B.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Oderich G.S.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 78
Initial page: 1162
ISSN: 0741-5214
Publisher: Elsevier
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-010-SCW
Resumo (PT):
Abstract (EN): Objective: Stenting of renal and mesenteric vessels may result in changes in velocity measurements due to arterial compliance, potentially giving rise to confusion about the presence of stenosis during follow-up. The aim of our study was to compare preoperative and postoperative changes in peak systolic velocity (PSV, cm/s) after placement of the celiac axis (CA), superior mesenteric artery (SMA) and renal artery (RAs) bridging stent grafts during fenestrated-branched endovascular aortic repair (FB-EVAR) for treatment of complex abdominal aortic aneurysms (AAA) and thoracoabdominal aortic aneurysms. Methods: Patients were enrolled in a prospective, nonrandomized single-center study to evaluate FB-EVAR for treatment of complex AAA and thoracoabdominal aortic aneurysms between 2013 and 2020. Duplex ultrasound examination of renal-mesenteric vessels were obtained prospectively preoperatively and at 6 to 8 weeks after the procedure. Duplex ultrasound examination was performed by a single vascular laboratory team using a predefined protocol including PSV measurements obtained with <60° angles. All renal-mesenteric vessels incorporated by bridging stent grafts using fenestrations or directional branches were analyzed. Target vessels with significant stenosis in the preoperative exam were excluded from the analysis. The end point was variations in PSV poststent placement at the origin, proximal, and mid segments of the target vessels for fenestrations and branches. Results: There were 419 patients (292 male; mean age, 74 ± 8 years) treated by FB-EVAR with 1411 renal-mesenteric targeted vessels, including 260 CAs, 409 SMAs, and 742 RAs. No significant variances in the mean PSVs of all segments of the CA, SMA, and RAs at 6 to 8 weeks after surgery were found as compared with the preoperative values (CA, 135 cm/s vs 141 cm/s [P = .06]; SMA, 128 cm/s vs 125 cm/s [P = .62]; RAs, 90 cm/s vs 83 cm/s [P = .65]). Compared with baseline preoperative values, the PSV of the targeted vessels showed no significant differences in the origin and proximal segment of all vessels. However, the PSV increased significantly in the mid segment of all target vessels after stent placement. Conclusions: Stent placement in nonstenotic renal and mesenteric vessels during FB-EVAR is not associated with a significant increase in PSVs at the origin and proximal segments of the target vessels. Although there is a modest but significant increase in velocity measurements in the mid segment of the stented vessel, this difference is not clinically significant. Furthermore, PSVs in stented renal and mesenteric arteries were well below the threshold for significant stenosis in native vessels. These values provide a baseline or benchmark for expected PSVs after renal-mesenteric stenting during FB-EVAR.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 32767
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The effect of the collateral cerebrovascular circulation on tolerance to carotid artery cross-clamping and on early outcome after carotid endarterectomy (2024)
Another Publication in an International Scientific Journal
Myrcha, P; Pinheiro, F; Rocha Neves, J; Myrcha, J; Gloviczki, P
Strengths and obvious limitations of transcervical carotid artery revascularization (2021)
Another Publication in an International Scientific Journal
Coelho, AP; de Borst, GJ
Open aortic reconstruction for middle aortic syndrome associated with right renal artery poststenotic aneurysm (2022)
Another Publication in an International Scientific Journal
Tenorio E.R.; Dias-Neto M; Ocasio L.; Macedo T.A.; Oderich G.S.
Management and outcomes of a vascular surgery department with sudden medical staff outbreak of COVID-19 (2020)
Another Publication in an International Scientific Journal
Pereira Neves, A; Rocha Neves, J; Cerqueira, A; Teixeira, J
Two-Stage Covered Endovascular Reconstruction of Aortic Bifurcation (CERAB) for Patients With Chronic Limb-Threatening Ischemia (2024)
Article in International Scientific Journal
Zydlewski, P; Hendiger, W; Rocha Neves, J; Kruszyna, ¿; Taranta, I

See all (19)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-30 at 21:14:47 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book