Você está em: Start > Publications > View > Air change rates in multi-family residential buildings in Northern Portugal
Map of Premises
Principal
Publication

Air change rates in multi-family residential buildings in Northern Portugal

Title
Air change rates in multi-family residential buildings in Northern Portugal
Type
Article in International Conference Proceedings Book
Year
2003
Authors
Manuel Pinto
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Carl-Axel Boman
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Hans Stymne
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vasco Peixoto de Freitas
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
Pages: 333-338
7th International Conference. Energy-Efficient Healthy Buildings
Singapore, 7 a 11 de Dezembro de 2003
Scientific classification
FOS: Engineering and technology > Civil engineering
CORDIS: Technological sciences > Engineering > Civil engineering
Other information
Abstract (EN): Existing technical recommendations and standards regarding natural ventilation in Portugal establish one air change rate, ACH, in main rooms (bedrooms and living rooms) and four ACH in service romms (kitchens and bathrooms). Admittedly these rates are not being observed in most residential buildings recently erected in Portugal. Two trials (May 2002 and January 2003, lasting approximately 2 weeks each) were carried out for the purpose of estimating the implementation of the rates in a two-bedroom flat which is inhabited and equipped with a "mixed" ventilation system: intake via self-adjusting ventilation inlets in the living room and bedrooms, natural exhaust in the bathroom assisted by discontinuous mechanical extraction in the kitchen. Some conclusions can bedrawn regarding the efficiency of the ventilation system used, namely the results of the study shows that the measured ventilation rate was irregular and lower than the Portuguese recommendations during both seasons. INDEX TERMS: Ventilation, dwellings, ACH, PFT, homogeneous emission technique
Language: English
Type (Professor's evaluation): Scientific
Notes: Vol II
No. of pages: 7
Documents
We could not find any documents associated to the publication with allowed access.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-15 at 08:02:24 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book