The METIS Warm Support Structure Final Design

Title
The METIS Warm Support Structure Final Design
Type
Article in International Conference Proceedings Book
Year
2022
Authors
Costa, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Amorim, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bone, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mercedes E Filho
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Lopo, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ngando, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Conference on Ground-Based and Airborne Instrumentation for Astronomy IX
Montreal, CANADA, JUL 17-22, 2022
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00X-E71
Abstract (EN): This article presents the final design of the METIS/ELT warm support structure subsystem. It provides the mechanical interface between the cryostat and the Nasmyth platform, and it consists of three substructures: the elevation platform, the cryostat alignment structure, and the instrument access platform. The elevation platform is connected to the Nasmyth platform and holds the cryostat alignment platform, consisting of seven legs connected to three nodes. The cryostat alignment platform is a hexapod holding the cryostat, allowing maintenance, alignment, and positioning. The instrument access platform allows human access to the cryostat, it bears the cable support system and is prepared to support the future Single Laser Adaptive Optics system. The subsystem requirements, design trade-offs, interface considerations, and the substructures' final design and simulation results will be detailed as presented to the METIS Final Design Review in 2022.
Language: English
Type (Professor's evaluation): Scientific