Go to:
Logótipo
Você está em: Start > Publications > View > Microbubble moving in blood flow in microchannels: effect on the cell-free layer and cell local concentration
Map of Premises
Principal
Publication

Microbubble moving in blood flow in microchannels: effect on the cell-free layer and cell local concentration

Title
Microbubble moving in blood flow in microchannels: effect on the cell-free layer and cell local concentration
Type
Article in International Scientific Journal
Year
2017
Authors
Bento, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sousa, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Yaginuma, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Garcia, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lima, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Miranda, JM
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 19
ISSN: 1387-2176
Publisher: Springer Nature
Other information
Authenticus ID: P-00M-CHM
Abstract (EN): Gas embolisms can hinder blood flow and lead to occlusion of the vessels and ischemia. Bubbles in microvessels circulate as tubular bubbles (Taylor bubbles) and can be trapped, blocking the normal flow of blood. To understand how Taylor bubbles flow in microcirculation, in particular, how bubbles disturb the blood flow at the scale of blood cells, experiments were performed in microchannels at a low Capillary number. Bubbles moving with a stream of in vitro blood were filmed with the help of a high-speed camera. Cell-free layers (CFLs) were observed downstream of the bubble, near the microchannel walls and along the centerline, and their thicknesses were quantified. Upstream to the bubble, the cell concentration is higher and CFLs are less clear. While just upstream of the bubble the maximum RBC concentration happens at positions closest to the wall, downstream the maximum is in an intermediate region between the centerline and the wall. Bubbles within microchannels promote complex spatio-temporal variations of the CFL thickness along the microchannel with significant relevance for local rheology and transport processes. The phenomenon is explained by the flow pattern characteristic of low Capillary number flows. Spatio-temporal variations of blood rheology may have an important role in bubble trapping and dislodging.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Yeasts identification in microfluidic devices using peptide nucleic acid fluorescence in situ hybridization (PNA-FISH) (2017)
Article in International Scientific Journal
Ferreira, AM; Cruz Moreira, D; Cerqueira, L.; Miranda, JM; Azevedo, NF
A simple microfluidic device for the deformability assessment of blood cells in a continuous flow (2015)
Article in International Scientific Journal
Raquel O. Rodrigues ; Diana Pinho; Vera Faustino; Rui Lima
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-29 at 20:54:51 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book