Go to:
Logótipo
Você está em: Start > Publications > View > Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation [Tomografia computorizada multicorte na avaliação de candidatos a implantação de prótese aórtica percutânea]
Map of Premises
Principal
Publication

Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation [Tomografia computorizada multicorte na avaliação de candidatos a implantação de prótese aórtica percutânea]

Title
Multislice computed tomography in the selection of candidates for transcatheter aortic valve implantation [Tomografia computorizada multicorte na avaliação de candidatos a implantação de prótese aórtica percutânea]
Type
Another Publication in an International Scientific Journal
Year
2011
Authors
De Morais, GP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bettencourt, N
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Silva, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ferreira, N
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sousa, O
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Caeiro, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rocha, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Carvalho, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Leite, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Braga, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fonseca, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Gama, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 30 No. 7-8
Pages: 717-726
ISSN: 0870-2551
Indexing
Other information
Authenticus ID: P-008-11H
Abstract (EN): Transcatheter aortic valve implantation is an emerging treatment option for severe symptomatic aortic stenosis in patients considered unsuitable for surgical valve replacement. The authors review the use of multislice computed tomography in the selection of candidates for transcatheter aortic valve replacement, procedural support and post-interventional follow-up. A single-center experience of the role of this imaging technique is also described. Multislice computed tomography is an essential imaging tool in the selection and exclusion of candidates for transcatheter aortic valve implantation, providing evaluation of coronary anatomy and the relationship of the coronary ostia with the aortic valve structure, and accurate analysis of the valve annulus and aortic root, left ventricular outflow tract, aorta and peripheral vascular access routes. Multislice computed tomography is also central to the choice of appropriate prosthesis size. In addition, it guides arterial puncture by image fusion techniques and enables correct prosthesis apposition to be verified. This review aims to describe the role of computed tomography in this increasingly common interventional valve procedure, providing an overview of current knowledge and applications.
Language: Portuguese
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The phenomenon of migration and cardiovascular risk factors (2018)
Another Publication in a National Scientific Journal
Campelo, M
Stabbed in the right place: The millimetric line between luck and disaster; [Apunhalado no sítio certo: a linha milimétrica entre a sorte e o desastre] (2023)
Another Publication in a National Scientific Journal
Amaral Marques, C; Mil Homens, F; Resende, CX; Fernandes, J; Gouveia, D; Pinho, P; Macedo, F
Social media use by cardiovascular healthcare professionals: Exploring a challenging and ever evolving frontier (2023)
Another Publication in a National Scientific Journal
Vilela, EM; José Pedro Nunes
Smoking in Portugal: Where do we stand today? (2019)
Another Publication in a National Scientific Journal
Pereira, AM
Sacubitril-valsartan in the real world: From theory to clinical practice (2018)
Another Publication in a National Scientific Journal
Fontes-Carvalho R

See all (628)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-17 at 20:32:15 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book