Artificial urinary sphincter or a second adjustable transobturator male system offer equivalent outcomes in patients whom required revision on the initial ATOMS device: An international multi-institutional experience
Type
Article in International Scientific Journal
Year
2021
Authors
Angulo, JC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Schonburg, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Giammo, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Queissert, F
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Gonsior, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Gonzalez Enguita, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Martins, FE
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rourke, K
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Francisco Cruz
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 40
Pages: 897-909
ISSN: 0733-2467
Publisher: Wiley-Blackwell
Other information
Authenticus ID: P-00T-KJA
Resumo (PT):
Abstract (EN): Aim To evaluate treatment options after surgical revision of adjustable transobturator male system (ATOMS) and the results of further incontinence implantation. Materials and Methods A retrospective multicenter study evaluating patients with surgical revision of ATOMS in academic institutions. Causes and factors affecting revision-free interval were studied and also the frequency of device explant and placement of second ATOMS or artificial urinary sphincter (AUS) at surgeon discretion. Operative results, complications (Clavien-Dindo), and efficacy (postoperative pad-test, pad-count, patient satisfaction, and patient global impression of improvement [PGI-I scale]) of each treatment option were compared. Results Seventy-eight out of 902 patients (8.65%) with ATOMS underwent surgical revision at 4.1 +/- 2.4 years mean follow-up and 75 (8.3%) were explanted. The main causes for revision included persistence of incontinence (35.9%) and scrotal port erosion (34.6%). Independent risk factors of the shortened revision-free interval were previous anti-incontinence surgery (HR, 1.83; 95% CI, 1.06-3.16; p = 0.007) and port erosion (HR, 1.83; 95% CI, 1.06-3.16; p = 0.0027). Fifty-eight (6.4%) received a second implant: 31 repeated ATOMS and 27 AUS. Operative time was longer for AUS (p = .003). The visual analog scale of pain at hospital discharge (p = 0.837) and postoperative complications (p = 0.154) were equivalent. The predominant cuff size for AUS was 4.5 cm (59.3%). Mean follow-up after the second implant was 29.1 +/- 25.8 months. Postoperative efficacy of secondary treatment results favored ATOMS based on pad-test (p = 0.016), pad-count (p = 0.029), patient satisfaction (p = 0.04), and PGI-I (p = 0.025). Conclusions ATOMS surgical revision due to different reasons generally leads to device explant. Rescue treatment is possible with ATOMS or AUS. No difference in postoperative complications was detected between secondary devices, but efficacy favors repeating ATOMS implantation.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 13
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

ATOMS (Adjustable Transobturator Male System) Is an Effective and Safe Second-Line Treatment Option for Recurrent Urinary Incontinence after Implantation of an AdVance/AdVance XP Fixed Male Sling? A Multicenter Cohort Analysis (2022)
Article in International Scientific Journal
Queissert, F; Rourke, K; Schonburg, S; Giammo, A; Gonsior, A; Gonzalez Enguita, C; Romero, A; Schrader, AJ; Francisco Cruz; Martins, FE; Dorado, JF; Angulo, JC
Adjustable Transobturator Male System (ATOMS) Infection: Causative Organisms and Clinical Profile (2021)
Article in International Scientific Journal
Angulo, JC; Rourke, K; Queissert, F; Giammo, A; Schonburg, S; Francisco Cruz; Martins, FE; Gonsior, A; Gonzalez Enguita, C

Of the same journal

The urinary and prostatic microbiome in non-neurogenic male LUTS/BPH: A systematic review (2024)
Another Publication in an International Scientific Journal
Pina-Vaz, T; Silva, AC; Silva, C; Miranda, I; Francisco Cruz; Silva, JA
Neurotrophins in Bladder Function: What Do We Know and Where Do We Go From Here? (2014)
Another Publication in an International Scientific Journal
Cruz C.D.
Is the Urothelium Intelligent? (2010)
Another Publication in an International Scientific Journal
Birder, LA; Kanai, AJ; Francisco Cruz; Moore, K; Fry, CH
Is it Possible to Regenerate the Underactive Detrusor? Part 2 Electrical Stimulation Therapies, Treatment of Bladder Outlet Obstruction, Constipation, and Pelvic Floor Disorders ICI-RS 2024 (2024)
Another Publication in an International Scientific Journal
Sinha, S; Gajewski, JB; Tarcan, T; Van Huele, A; Francisco Cruz; Martinez, EM; Przydacz, M; Kheir, GB; Lombardo, R; Wein, A; Abrams, P

See all (26)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-23 at 06:40:09 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book