Go to:
Logótipo
Você está em: Start > Publications > View > Computational analysis for stress intensity factor (KI) measuring in metal-ceramic interface
Map of Premises
Principal
Publication

Computational analysis for stress intensity factor (KI) measuring in metal-ceramic interface

Title
Computational analysis for stress intensity factor (KI) measuring in metal-ceramic interface
Type
Article in International Conference Proceedings Book
Year
2019
Authors
Elza M. M. Fonseca
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Joana F. Piloto
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Maria G. Fernandes
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Renato Natal Jorge
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 15-18
Proceedings of the 5th International Conference on Biodental Engineering (BIODENTAL 2018)
Porto, Portugal, June 22-23, 2018
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00Q-E02
Abstract (EN): The purpose of this work is to study the effect of cracks on the behavior of SIF (KI) in single edge crack of a bi-material interface, as metal-ceramic dental application. Metals, alloys, ceramics and others materials have been used in dentistry as restorative materials. However, a challenging aspect in ceramic materials is their restricted loading capability due to the low fracture toughness. In this work, the finite element method was used to evaluate the SIFs and to model a single edge crack in a metal (NiCr) and ceramic (KKM95-VITA) model subjected mode I loading.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4