Go to:
Logótipo
Você está em: Start > Publications > View > Reducing computation time by Monte Carlo method: an application in determining axonal orientation distribution function
Map of Premises
Principal
Publication

Reducing computation time by Monte Carlo method: an application in determining axonal orientation distribution function

Title
Reducing computation time by Monte Carlo method: an application in determining axonal orientation distribution function
Type
Article in International Conference Proceedings Book
Year
2016
Authors
Lori, NF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Lavrador, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fonseca, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Travasso, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sousa, N
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Alves, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 95-105
World Conference on Information Systems and Technologies (WorldCIST)
Recife, BRAZIL, MAR 22-24, 2016
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00K-AHD
Abstract (EN): Diffusion MRI (dMRI) is highly sensitive in detecting early cerebral ischemic changes in acute stroke, and in pre-clinical assessment of white matter (WM) anatomy using tractography, thus being an important component of health informatics. In clinical settings, the computation time is critical, and so finding forms of reducing the processing time in high computation processes such as Diffusion Spectrum Imaging (DSI) dMRI data processing is extremely relevant. We analyse here a method for reducing the computation of the dMRI-based axonal orientation distribution function h by using a Monte Carlo sampling-based methods for voxel selection, and so obtained a reduction in required data sampling of about 20%. In this work we show that the convergence to the correct value in this type of dMRI data-processing is linear and not exponential, implying that the Monte Carlo approach in this type of dMRI data processing improves its speed, but further improvements are needed.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Processing Time Reduction: an Application in Living Human High-Resolution Diffusion Magnetic Resonance Imaging Data (vol 40, 243, 2016) (2017)
Other Publications
Lori, NF; Ibanez, A; Lavrador, R; Fonseca, L; Santos, C; Travasso, R; Pereira, A; Rosaldo J. F. Rossetti; Sousa, N; Alves, V
Processing Time Reduction: an Application in Living Human High-Resolution Diffusion Magnetic Resonance Imaging Data (2016)
Article in International Scientific Journal
Lori, NF; Ibanez, A; Lavrador, R; Fonseca, L; Santos, C; Travasso, R; Pereira, A; Rosaldo J. F. Rossetti; Sousa, N; Alves, V
Erratum to: Processing Time Reduction: an Application in Living Human High-Resolution Diffusion Magnetic Resonance Imaging Data (2017)
Article in International Scientific Journal
Lori, NF; Ibáñez, A; Lavrador, R; Fonseca, L; Santos, C; Travasso, R; Pereira, A; Rosaldo J. F. Rossetti; Sousa, N; Alves, V
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-13 at 14:43:11 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book