Validation of a low intrusiveness heart rate sensor for stress assessment

Title
Validation of a low intrusiveness heart rate sensor for stress assessment
Type
Article in International Scientific Journal
Year
2017
Authors
Pereira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Almeida, PR
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
The Journal is awaiting validation by the Administrative Services.
Vol. 3
ISSN: 2057-1976
Other information
Authenticus ID: P-00N-1J0
Abstract (EN): Heart rate variability (HRV) analysis has been used as a quantitative marker of the autonomous nervous system activity to measure mental stress. Wearable sensors have been emerging as a solution to collect HRV data for stress assessment in a real context, however such studies raise additional requirements. The wearable system must be minimally obtrusive to allow the subjects to perform their tasks without interference, and inconspicuous to avoid the anxiety associated with wearing medical devices in public. The purpose of this study was to quantify the accuracy trade-off in the use of a chest band heart rate sensor that is less intrusive and less costly than a wearable electrocardiogram (ECG). The HRV metrics extracted from a chest band heart rate monitor, Zephyr HxM (TM) (Zph (TM)), were compared with those extracted from an ECG certified medical device, Vital Jacket (TM) (VJ (TM)). The two systems were worn simultaneously. under laboratory conditions by a population of 14 young and healthy subjects, aged 20 to 26 years, under the stress induced by the Trier Social Stress Test (TSST) procedure. The results showed a mean difference between RR intervals of 9 ms; a. root-mean square error. (RMSE) of less than 8% and. a Pearson's correlation higher than 0.946, considering all TSST phases. In the HRV analysis, the average of all normal intervals (AVNN) showed errors less than 2% between the two systems with a correlation higher than 0.99 for all TSST phases. We thus conclude that the used chest band sensor represents an alternative to the current wearable medical devices to monitor RR intervals, and could be used for mental stress monitoring similar to the TSST protocol.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Heart rate variability metrics for fine-grained stress level assessment (2017)
Article in International Scientific Journal
Pereira, T; Almeida, PR; Cunha, JPS; Ana Aguiar

Of the same journal

Tribocorrosion studies on diamond-like carbon film deposited by PECVD on 304 stainless steel in simulated body fluid (2019)
Article in International Scientific Journal
Oliveira, SMM; Barzotto, ILM; Vieira, L; Sene, A; Radi, PA; Sonia Fraga; Bessa, MJ; Teixeira, JP; Carvalho, ICS; da Silva, NS
Fibrous structures in augmentation for rotator cuff repair: an experimental comparison (2018)
Article in International Scientific Journal
T. Peixoto; F. A. M. Pereira; P. L. Silva; Rui Miranda Guedes; J. Torres; Maria Ascensão Lopes
Dual pulsed laser deposition of Ag nanoparticles on calcium phosphate coatings for biomedical applications (2022)
Article in International Scientific Journal
Lopez-Alvarez, M; Gonzalez-Rodriguez, L; Gontad, F; Teixeira-Santos, R; Doiro, M; Alvarez-Gomez, L; Filipe Mergulhão; Gonzalez, P; Serra, J
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-26 at 12:43:37 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book