Go to:
Logótipo
Você está em: Start > Publications > View > Instrumented insole system for ambulatory and robotic walking assistance: First advances
Map of Premises
Principal
Publication

Instrumented insole system for ambulatory and robotic walking assistance: First advances

Title
Instrumented insole system for ambulatory and robotic walking assistance: First advances
Type
Article in International Conference Proceedings Book
Year
2017
Authors
Figueiredo, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ferreira, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Costa, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sepúlveda, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Moreno, JC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos, CP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Indexing
Other information
Authenticus ID: P-00M-YKD
Abstract (EN): Current research highlights the emergent need for the development of wearable, calibrated, and accurate sensory systems for ambulatory human gait analysis. The purpose of this work is to develop a lightweight and calibrated instrumented insole system for the real-time monitoring of gait events in healthy, pathological and robotic-assisted gait. We designed the insole with four force sensing resistors (FSRs) to detect four gait events. We also implemented an electronic interface for the data acquisition and processing and the wireless transmission with the motherboard and the user interface. The validation involved 3 healthy female subjects, which reported that this prototype is flexible, lightweight and comfortable for daily usage. Results showed a maximal error of 6.02±3.02% in the detection of foot flat due to the small sensing area of FSRs placed on the first and fifth metatarsus. Future challenges comprise aesthetic and functional improvements and a more comprehensive validation.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Proceedings of the 3rd IPLeiria's International Health Congress Abstracts (2016)
Article in International Scientific Journal
Tomás, CC; Oliveira, E; Sousa, D; Uba Chupel, M; Furtado, G; Rocha, C; Lopes C; Ferreira, P; Alves, C; Gisin, S; Catarino, E; Carvalho, N; Coucelo, T; Bonfim, L; Silva, C; Franco, D; González, JA; Jardim, HG; Silva, R; Baixinho, CL...(mais 1673 authors)