Go to:
Logótipo
Você está em: Start > Publications > View > Magnetic field sensor with Terfenol-D thin-film coated FBG
Map of Premises
Principal
Publication

Magnetic field sensor with Terfenol-D thin-film coated FBG

Title
Magnetic field sensor with Terfenol-D thin-film coated FBG
Type
Article in International Conference Proceedings Book
Year
2012
Authors
Silva, RM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Chesini, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Gouveia, CJ
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Lobo Ribeiro, ABL
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Frazao, O
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Cordeiro, CMB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Jorge, PAS
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
22nd International Conference on Optical Fiber Sensors (OFS)
Beijing, PEOPLES R CHINA, OCT 15-19, 2012
Other information
Authenticus ID: P-002-EEN
Abstract (EN): In this work a magnetic field sensor based on an FBG coated with a thin film of Terfenol-D is presented. The sensor was tested with two optical interrogation systems: one, a scanning laser system with a 1 pm resolution, and the other a differential white light interferometer (WLI). The results obtained in the magnetic field range of 20 mT to 100 mT, show the possibility of increasing the magnetic field measurement resolution, with temperature fluctuations invariance, by a factor of 4.5 when using the WLI system.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-10 at 16:13:19 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book