Go to:
Logótipo
Você está em: Start > Publications > View > Combined Microfiber Knot Resonator and Focused Ion Beam-Milled Mach-Zehnder Interferometer for Refractive Index Measurement
Map of Premises
Principal
Publication

Combined Microfiber Knot Resonator and Focused Ion Beam-Milled Mach-Zehnder Interferometer for Refractive Index Measurement

Title
Combined Microfiber Knot Resonator and Focused Ion Beam-Milled Mach-Zehnder Interferometer for Refractive Index Measurement
Type
Article in International Conference Proceedings Book
Year
2017
Authors
Gomes, AD
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Andre, RM
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Warren Smith, SC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Dellith, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Becker, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rothhardt, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Frazao, O
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
25th International Conference on Optical Fibre Sensors (OFS)
SOUTH KOREA, APR 24-28, 2017
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-00M-T1B
Abstract (EN): A Mach-Zehnder interferometer was created from a cavity milled in the taper region next to a microfiber knot resonator. A focused ion beam was used to mill the cavity with 47.8 mu m in length. The microfiber knot resonator was created from an 11 mu m diameter taper, produced using a filament fusion splicer. After milling the cavity, the microfiber knot resonator spectrum is still visible. The final response of the presented sensor is a microfiber knot resonator spectrum modulated by the Mach-Zehnder interference spectrum. A preliminary result of -8935 +/- 108 nm/RIU was obtained for the refractive index sensitivity of the cavity component in a refractive index range of n = 1.333 to 1.341. Simultaneous measurement of refractive index and temperature using this combined structure is a future goal.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-17 at 02:09:24 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book