Respiration Effect on Wavelet-Based ECG T-Wave End Delineation Strategies

Title
Respiration Effect on Wavelet-Based ECG T-Wave End Delineation Strategies
Type
Article in International Scientific Journal
Year
2012
Authors
Noriega, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pablo Martinez, JP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Laguna, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bailon, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 59
Pages: 1818-1828
ISSN: 0018-9294
Publisher: IEEE
Other information
Authenticus ID: P-002-8HD
Abstract (EN): The main purpose of this paper is to study the influence of the mechanical effect of respiration over the T-wave end delineation. We compared the performance of an automatic delineation system based on the wavelet transform (WT), considering single lead (SL), global delineation locations obtained from SL annotations (SLR), and multilead (ML) approaches. The linear relation between the variations on T-wave end locations obtained with each of the methods and the mechanical effect of respiration was quantified using spectral coherence and ARARX modeling both in simulated signals and in real data. We also explored the evolution of the vectorcardiographic spatial loop using the projection on the main direction of the WT in the region close to the T-wave end (T-e) and its relation with respiration. The dispersion of the additional T-wave end location error due to respiration was reduced by 15% using SLR with respect to SL, while ML allows for a reduction of around 40%. The percentage of that error correlated with respiration was in average 99% using SL while 82% and 72% using SLR and ML, respectively. Thus, results suggest that ML is the most adequate strategy for T-wave delineation, allowing the reduction of the instability of T-wave end location caused by respiration.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

SIGIF: A digital signal interchange format with application in neurophysiology (1997)
Article in International Scientific Journal
Cunha, MB; Cunha, JPS; Silva, TOE
QT variability and HRV interactions in ECG: Quantification and reliability (2006)
Article in International Scientific Journal
Almeida, R; Gouveia, S; Rocha, AP; Pueyo, E; Martinez, JP; Laguna, P
Pulmonary Hypertension Detection from Heart Sound Analysis (2025)
Article in International Scientific Journal
Gaudio, A; Giordano, N; Elhilali, M; Schmidt, S; Renna, F
MULTIPROCESSOR ELECTROENCEPHALOGRAM (EEG) ANALYZER (1983)
Article in International Scientific Journal
Pedro Guedes de Oliveira; José Principe; A. M. Cruz; A. M. Tomé
Multilead ECG Delineation Using Spatially Projected Leads From Wavelet Transform Loops (2009)
Article in International Scientific Journal
Rute Almeida; Juan P Pablo Martinez; Ana Paula Rocha; Pablo Laguna

See all (19)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-07-01 at 23:57:54 | Acceptable Use Policy | Data Protection Policy | Complaint Portal