Publication

Modelling and simulation of a ventilated double window

Title
Modelling and simulation of a ventilated double window
Type
Article in International Scientific Journal
Year
2011
Authors
Jorge S. Carlos
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pedro D. Silva
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
J.P. Castro-Gomes
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 31 No. 6-7
Pages: 93-102
ISSN: 1359-4311
Publisher: Elsevier
Other information
Authenticus ID: P-002-Y1T
Abstract (EN): Double windows are a currently adopted construction system in Portuguese residential buildings to prevent air leakage and thermal discomfort. We have changed this construction system so that it could be able to pre-heat the ventilation air between the windows. Simple changes consist in introducing vents at the base of the outer window to allow a supply of fresh air. Heat that escapes from inside through the inner window and solar radiation heat up the air between the two windows. Due to wind pressure and stack effect, the air rises and enters the room through a vent at the inside top of the system warmer than the outdoor air. A simulation program was built and validated with the use of test facilities, where different configurations of the system were tested. This paper presents the mathematical model and some results of a simulation work based on it. Parametrical studies were carried out by varying the airflow rate, the outdoor air temperature and the solar irradiance to predict the temperature rise and the useful energy of the delivered air. Results indicate an encouraging thermal performance of the ventilated double window offering itself as an alternative to cold natural ventilation.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Real climate experimental study of two double window systems with preheating of ventilation air (2010)
Article in International Scientific Journal
Helena Corvacho; Jorge S. Carlos; Pedro D. Silva; J.P. Castro-Gomes

Of the same journal

“Recent Advances in Building Air Conditioning Systems for Buildings”. (2006)
Article in International Scientific Journal
Afonso, C.F.A.
Ventilation terminals for use with light pipes in buildings: a CFD study (2000)
Article in International Scientific Journal
Szabolcs Varga; Armando C. Oliveira
Ventilation Terminals For Use With Light Pipes In Buildings (2000)
Article in International Scientific Journal
Szabolcs Varga; Armando C. Oliveira
Thermal performance of a PCM firefighting suit considering transient periods of fire exposure, post - fire exposure and resting phases (2021)
Article in International Scientific Journal
Jorge A. Fonseca; Soraia F. Neves; João Bernardo Campos
Thermal performance of a novel air conditioning system using a liquid desiccant (2000)
Article in International Scientific Journal
Armando C. Oliveira; Clito F. Afonso; Saffa B. Riffat; Prince S. Doherty

See all (30)