Go to:
Logótipo
Você está em: Start > Publications > View > Diffusion characteristics of ethylene glycol in skeletal muscle
Map of Premises
Principal
Publication

Diffusion characteristics of ethylene glycol in skeletal muscle

Title
Diffusion characteristics of ethylene glycol in skeletal muscle
Type
Article in International Scientific Journal
Year
2015
Authors
Oliveira, LM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Maria Inês Barbosa de Carvalho
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Nogueira, EM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Tuchin, VV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 20
Final page: 051019
ISSN: 1083-3668
Publisher: SPIE
Other information
Authenticus ID: P-00A-348
Abstract (EN): Part of the optical clearing study in biological tissues concerns the determination of the diffusion characteristics of water and optical clearing agents in the subject tissue. Such information is sufficient to characterize the time dependence of the optical clearing mechanisms-tissue dehydration and refractive index (RI) matching. We have used a simple method based on collimated optical transmittance measurements made from muscle samples under treatment with aqueous solutions containing different concentrations of ethylene glycol (EG), to determine the diffusion time values of water and EG in skeletal muscle. By representing the estimated mean diffusion time values from each treatment as a function of agent concentration in solution, we could identify the real diffusion times for water and agent. These values allowed for the calculation of the correspondent diffusion coefficients for those fluids. With these results, we have demonstrated that the dehydration mechanism is the one that dominates optical clearing in the first minute of treatment, while the RI matching takes over the optical clearing operations after that and remains for a longer time of treatment up to about 10 min, as we could see for EG and thin tissue samples of 0.5 mm. (C) 2015 Society of Photo-Optical Instrumentation Engineers (SPIE)
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Skeletal muscle dispersion (400-1000 nm) and kinetics at optical clearing (2018)
Another Publication in an International Scientific Journal
Oliveira, LM; Maria Inês Barbosa de Carvalho; Nogueira, EM; Tuchin, VV
Diffusion characteristics of ethylene glycol in skeletal muscle (vol 20, 051019, 2015) (2015)
Other Publications
Oliveira, LM; Maria Inês Barbosa de Carvalho; Nogueira, EM; Tuchin, VV

Of the same journal

Diffusion characteristics of ethylene glycol in skeletal muscle (vol 20, 051019, 2015) (2015)
Other Publications
Oliveira, LM; Maria Inês Barbosa de Carvalho; Nogueira, EM; Tuchin, VV
Review of fiber-optic pressure sensors for biomedical and biomechanical applications (2013)
Article in International Scientific Journal
Paulo Roriz; Orlando Frazao; Antonio B Lobo Ribeiro; Jose L Santos; Jose A Simoes
In vivo measurement of the pressure signal in the intervertebral disc of an anesthetized sheep (2014)
Article in International Scientific Journal
Paulo Roriz; Joao M C Ferreira; Jose C Potes; Maria T Oliveira; Orlando Frazao; Jose Luis Santos; Jose Antonio D de Oliveira Simoes
Discriminating adenocarcinoma from normal colonic mucosa through deconvolution of Raman spectra (2011)
Article in International Scientific Journal
Lopes, PC; Moreira, JA; Almeida, A; Esteves, A; Gregora, I; Ledinsky, M; Lopes, JM; Henrique, R; Oliveira, A
Aptamer-based fiber sensor for thrombin detection (2016)
Article in International Scientific Journal
Coelho, L; de Almeida, JMMM; Santos, JL; Jorge, PAS; Martins, MCL; Viegas, D; Queiros, RB
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-09-14 at 15:07:24 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book