Go to:
Logótipo
Você está em: Start > Publications > View > Influence of load shedding in the voltage stability of an electric power system using trajectory sensitivity analysis
Map of Premises
Principal
Publication

Influence of load shedding in the voltage stability of an electric power system using trajectory sensitivity analysis

Title
Influence of load shedding in the voltage stability of an electric power system using trajectory sensitivity analysis
Type
Article in International Conference Proceedings Book
Year
2010
Authors
Monteiro Pereira, RM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Machado Ferreira, CM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernando Maciel Barbosa
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Conference proceedings International
2010 45th International Universities' Power Engineering Conference, UPEC 2010
Cardiff, 31 August 2010 through 3 September 2010
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-007-WZY
Abstract (EN): Trajectory sensitivity analysis can provide valuable insights into the security of an electric power system. There is a strong correlation relating the system stability and the corresponding trajectory sensitivity. In this paper it is analyzed the influence of load shedding in the voltage stability of an electric power system using trajectory sensitivity analysis. It is recognized that voltage instability and collapse have led to major system failures. The emergency load shedding is one of the most important methods to preserve the system stability. In this study different values of load shedding were used to avoid voltage collapse. The automatic voltage regulators of the generating units and the turbine speed governors were modelled. Different load models were used and the under load tap changers were also taken into account. The simulation results were obtained using EUROSTAG program and post-processing module developed using the Matlab software package.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Trajectory sensitivity analysis of dynamic voltage stability in power systems (2011)
Article in International Conference Proceedings Book
Monteiro Pereira, RM; Machado Ferreira, CM; Fernando Maciel Barbosa
DFIG performance assessment during low voltage ride through in the dynamic voltage stability of an electric power system (2011)
Article in International Conference Proceedings Book
Monteiro Pereira, RM; Machado Ferreira, CM; Fernando Maciel Barbosa
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-18 at 02:58:02 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book