Go to:
Logótipo
Você está em: Start > Publications > View > Stress analysis of the tympanic membrane through image
Map of Premises
Principal
Publication

Stress analysis of the tympanic membrane through image

Title
Stress analysis of the tympanic membrane through image
Type
Article in International Conference Proceedings Book
Year
2012
Authors
garbe, c
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
parente, m
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
martins, p
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
natal jorge, r
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
gentil, f
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
paco, j
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 311-314
3rd ECCOMAS Thematic Conference on Computational Vision and Medical Image Processing (VipIMAGE)
Olhao, PORTUGAL, OCT 12-14, 2011
Indexing
Other information
Authenticus ID: P-008-29G
Abstract (EN): To better understand the ear functioning, a biomechanical study of the tympanic ossicular chain of the middle ear was made. This chain consists of the tympanic membrane (which has 3 layers), three ossicles (malleus, incus and stapes), six ligaments, tendons and respective two muscles. The objective of this study was to analyze the stresses of the tympanic membrane through images, allowing a comparison of the different frequencies used. A geometric model of the tympanic membrane and ossicles was built through images of Computerized Axial Tomography (CAT). The discretization of this model was done using the finite element method, based on the ABAQUS software. The mechanical properties were obtained from previous work. The results were compared in the dynamic analysis of the tympanic ossicular chain for a frequency range between 100 Hz and 10 kHz, for a sound pressure level of 105 dB SPL, applied on the tympanic membrane. We can observe differences for each frequency in the tympanic membrane.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-19 at 15:53:27 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book