Go to:
Logótipo
Você está em: Start > Publications > View > LARGE RANGE COHERENCE TUNED FIBER OPTIC INTERFEROMETRIC SYSTEM FOR APPLICATION IN ACCELEROMETERS
Map of Premises
Principal
Publication

LARGE RANGE COHERENCE TUNED FIBER OPTIC INTERFEROMETRIC SYSTEM FOR APPLICATION IN ACCELEROMETERS

Title
LARGE RANGE COHERENCE TUNED FIBER OPTIC INTERFEROMETRIC SYSTEM FOR APPLICATION IN ACCELEROMETERS
Type
Article in International Scientific Journal
Year
1992
Authors
RIBEIRO, ABL
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
SANTOS, JL
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
JACKSON, DA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 63
Pages: 3586-3589
ISSN: 0034-6748
Scientific classification
FOS: Engineering and technology > Other engineering and technologies
Other information
Authenticus ID: P-001-PF6
Abstract (EN): A low coherence interferometric system with large tracking range and self-initialization to be used for remote signal processing of fiber optic accelerometers is investigated. The tracking range of the low coherence system is 1.1 mm at low frequency. Phase resolution better than 1 mrad/ square-root Hz at frequencies below 600 Hz is obtained, with a dynamic range of almost-equal-to 90 dB. Data are presented which show that if the system were used to process the output from a compliant cylinder-type accelerometer, resolutions of approximately 10(-7) g/ square-root Hz could be achieved.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Analysis of the reflective-matched fiber Bragg grating sensing interrogation scheme (1997)
Article in International Scientific Journal
Ribeiro, ABL; Ferreira, LA; Santos, JL; Jackson, DA

Of the same journal

Versatile Seebeck and electrical resistivity measurement setup for thin films (2021)
Article in International Scientific Journal
Ferreira Teixeira, S; F.C. Carpinteiro; araujo, j. p.; Sousa, JB; pereira, a. m.
Versatile, high sensitivity, and automatized angular dependent vectorial Kerr magnetometer for the analysis of nanostructured materials (2011)
Article in International Scientific Journal
teixeira, j. m.; lusche, r.; ventura, j.; fermento, r.; carpinteiro, f.; araujo, j. p.; sousa, j. b.; cardoso, s.; freitas, p. p.
Two fast VME transient recorder systems with 12 bits and multiple differential inputs (1999)
Article in International Scientific Journal
Correia, C; Combo, A; Correia, M; Simoes, JB; Coelho, P; Carvalho, BB; Sousa, J; Varandas, CAF
Transversal load measurement based on twisted optical fibers (2005)
Article in International Scientific Journal
Pinto, NMP; Frazao, O; Baptista, JM; Santos, JL
Self-referencing resonant fiber optic intensity sensor based on a Mach-Zehnder topology (1996)
Article in International Scientific Journal
Baptista, JM; Cavaleiro, PM; Santos, JL

See all (16)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-20 at 15:48:36 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book