Go to:
Logótipo
Você está em: Start > Publications > View > Access to computerised analysis of intrapartum cardiotocographs improves clinicians' prediction of newborn umbilical artery blood pH
Map of Premises
Principal
Publication

Access to computerised analysis of intrapartum cardiotocographs improves clinicians' prediction of newborn umbilical artery blood pH

Title
Access to computerised analysis of intrapartum cardiotocographs improves clinicians' prediction of newborn umbilical artery blood pH
Type
Article in International Scientific Journal
Year
2010
Authors
Ayres de Campos, D
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Costa, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Bernardes, J
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 117
Pages: 1288-1293
ISSN: 1470-0328
Publisher: Wiley-Blackwell
Scientific classification
FOS: Medical and Health sciences > Clinical medicine
Other information
Authenticus ID: P-003-34X
Abstract (EN): Objective To evaluate the impact of access to computerised cardiotocograph (CTG) analysis on reproducibility and accuracy of clinicians' predictions of umbilical artery blood pH (UAB pH) and 5-minute Apgar score. Design Prospective evaluation of pre-recorded cases. Setting A tertiary-care university hospital. Population From databases of intrapartum CTGs acquired in singleton term pregnancies, 204 tracings with low signal loss and short time interval to delivery were consecutively selected. Methods Tracings were randomly assigned to computer analysis by the Omniview-SisPorto 3.5 (R) system (study group n = 104) or to no analysis (control group n = 100). Three experienced clinicians evaluated all tracing printouts independently and were asked to predict the newborns' UAB pH and 5-minute Apgar scores from them. Main outcome measures Interobserver agreement (measured by the intraclass correlation coefficient [ICC]) and accuracy in prediction of neonatal outcomes with 95% CI. Results Agreement on prediction of UAB pH was significantly higher in the study group (ICC = 0.70; 95% CI 0.61-0.77) than in the control group (ICC = 0.43; 95% CI 0.21-0.60), and a trend towards better agreement was also seen in estimation of 5-minute Apgar scores (ICC = 0.55; 95% CI 0.38-0.68 versus ICC = 0.43; 95% CI 0.25-0.57). Observers predicted UAB pH values correctly within a 0.10 margin in 70% of cases in the study group (95% CI 0.61-0.79) versus 46% in the control group (95% CI 0.35-0.56). They predicted 5-minute Apgar scores within a margin of one in 81% of cases in the study group (95% CI 0.73-0.88) and in 70% of cases in the control group (95% CI 0.61-0.79). Conclusions Prediction of UAB pH is more reproducible and accurate when clinicians have access to computerised analysis of CTGs.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Single dose versus multiple dose of antibiotic prophylaxis in caesarean section: a systematic review and meta-analysis (2017)
Another Publication in an International Scientific Journal
Pinto Lopes, R; Sousa Pinto, B; Azevedo L
Producing valid statistics when legislation, culture, and medical practices differ for births at or before the threshold of survival: Report of a European workshop (2020)
Another Publication in an International Scientific Journal
Smith, LK; Blondel, B; Zeitlin, J; Haidinger, G; Alexander, S; Kolarova, R; Rodin, U; Kyprianou, T; Velebil, P; Mortensen, L; Sakkeus, L; Gissler, M; Blondel, B; Heller, G; Lack, N; Antsaklis, A; Berbik, I; Olafsdottir, HS; Bonham, S; Cuttini, M...(mais 21 authors)
Maternal fever in term labour in relation to fetal tachycardia, cord artery acidaemia and neonatal infection (1998)
Another Publication in an International Scientific Journal
Joao Bernardes; Costa-Pereira A; Herbst, A; Wolner Hanssen, P; Ingemarsson, I
Computerized estimation of the baseline fetal heart rate in labour: the low frequency line (1998)
Another Publication in an International Scientific Journal
Joao Bernardes; Costa-Pereira A; Mongelli, M; Sahota, D; Chung, TKH; Chang, AMZ
Computer quantification of short-term variability as an adjunct to fetal electrocardiographic monitoring (2007)
Another Publication in an International Scientific Journal
Diogo Ayres de Campos; Joao Bernardes; Kwee, A; Westerhuis, M; Visser, GHA

See all (17)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-15 at 00:51:31 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book