SEQUENTIAL DETERMINATION OF CALCIUM AND NITRATE IONS IN WATERS BY POTENTIOMETRIC FLOW-INJECTION

Title
SEQUENTIAL DETERMINATION OF CALCIUM AND NITRATE IONS IN WATERS BY POTENTIOMETRIC FLOW-INJECTION
Type
Article in International Scientific Journal
Year
1993
Authors
ALONSOCHAMARRO, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
BARTROLI, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
JUN, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
CONCEICAO, M
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
MONTENEGRO, BSM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: The AnalystImported from Authenticus Search for Journal Publications
Vol. 118
Pages: 1527-1532
ISSN: 0003-2654
Scientific classification
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-001-MBX
Abstract (EN): A compact and robust flow injection system for the simultaneous determination of calcium and nitrate in waters, with sequential detection by potentiometric sensors, is described. The effects of silver ionic strength adjuster (ISA) or lead ISA carrier solutions on the response of the tubular electrodes used and on the ability of the system to control interferences were studied in detail. Under the selected experimental conditions, the response slope and lower limit of linear response were 53.4 mV per decade and 10(-4.3) mol l(-1) for the nitrate sensor and 31.3 mV per decade and 10(-4.75) mol l(-1) for the calcium sensor. The reproducibility (relative standard deviation) was better than 1% and the sample throughput was approximately 145 h(-1). The results provided by the flow system were shown to be accurate, reproducible and free from interferences. The results obtained for calcium and nitrate in 23 samples with the flow injection system and with a reference method were in good agreement with each other. No significant interferences from other ions, especially chloride and hydrogencarbonate, were observed in surface waters, excluding those with a high saline content. The sequential method described was shown to be useful in routine determinations with a high sampling rate at a low cost.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 6
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The role of ionic liquids in the biocatalytic evaluation of bisphenol levels as contaminant: an automatic approach (2018)
Article in International Scientific Journal
Costa, AR; Passos, MLC; Pinto, PCAG; Pereira, SAP; Lucia L M F S Saraiva
Stochastic detection and characterisation of individual ferrocene derivative tagged graphene nanoplatelets (2016)
Article in International Scientific Journal
Wu, HY; Lin, QW; Batchelor McAuley, C; Goncalves, LM; Lima, CFRAC; Compton, RG

See all (47)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-21 at 21:25:09 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book