Characterization of the electrode-skin impedance of textile electrodes

Title
Characterization of the electrode-skin impedance of textile electrodes
Type
Article in International Conference Proceedings Book
Year
2014
Authors
Cristina Oliveira
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications Without AUTHENTICUS Without ORCID
José Machado Da Silva
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 1-6
2014 29th Conference on Design of Circuits and Integrated Systems, DCIS 2014
26 November 2014 through 28 November 2014
Indexing
INSPEC
Scientific classification
FOS: Engineering and technology > Electrical engineering, Electronic engineering, Information engineering
CORDIS: Technological sciences > Engineering > Biomedical enginnering
Other information
Authenticus ID: P-00G-EPW
Abstract (EN): Wearable systems are expected to contribute for improving traditional biopotential signals monitoring devices due to higher freedom and unobtrusiveness provided to the wearer. Textile electrodes present advantages compared with the conventional Ag/AgCl electrodes for the capturing of biopotentials, namely in terms of skin irritation due to the hydrogel and the need of a technician to place the electrodes on the correct positions. Due to the lack of hydrogel, textile electrodes present different electrical contact characteristics. The skin-electrode impedance is an important feature since it affects the captured signal quality. Although a low impedance is desired, a comfortable wearable system should not require the electrodes to be covered by the hydrogel or be moistened. A forearm sleeve provided with textile electrodes was used to study the electrode-skin impedance and the signal-to-noise ratio (SNR) of surface electromyographic (EMG) signals on a long-term use basis. The sleeve can be adjusted for different levels of tightening to control the pressure applied on the electrodes. The obtained results provide valuable information on the pressure that the textile garments of a sleeve or vest should apply on the recording electrodes, in order to assure a good electrical and mechanical contact between the electrodes and the skin and decrease the noise due to motion. It was observed that the electrode-skin impedance measurement alone is not sufficient to establish a relation with the SNR. The extraction of parameters from an electrical equivalent model of the electrode-skin interface allows to determine a relation with the model parameters and the SNR. The evaluation of these parameters during long-term monitoring will allow assessing the quality of biopotential measurements in textile electrodes. © 2014 IEEE.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Implantable Flexible Pressure Measurement System Based on Inductive Coupling (2015)
Article in International Scientific Journal
Cristina Oliveira; José Machado Da Silva
Fault detection system for a stent-graft endoleakage monitor (2012)
Article in International Conference Proceedings Book
Cristina Oliveira; José Machado Da Silva

Of the same scientific areas

Special Issue on Retinal Image Analysis (2013)
Another Publication in an International Scientific Journal
Ana Maria Mendonça
Image Analysis and Modeling in Ophthalmology (2014)
Book
E. Y. K. Ng; U. Rajendra Acharya; Aurélio Campilho; Jasjit S. Suri
Early Detection of Electroencephalogram Temporal Events in Alzheimer’s Disease (2017)
Chapter or Part of a Book
Diamantino Freitas; Pedro Miguel de Luís Rodrigues; João Paulo Teixeira; Dílio Alves; Maria Carolina Garrett
Detection of the Occupation of the Costal Diaphragmatic Angle in Chest Radiographs (2000)
Article in National Scientific Journal
Luís Alexandre; Mário Silva; Aurélio Campilho

See all (26)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-10 at 03:51:51 | Privacy Policy | Personal Data Protection Policy | Whistleblowing | Electronic Yellow Book