Go to:
Logótipo
Você está em: Start > Publications > View > Melt Electrowritten Biodegradable Mesh Implants with Auxetic Designs for Pelvic Organ Prolapse Repair
Map of Premises
Principal
Publication

Melt Electrowritten Biodegradable Mesh Implants with Auxetic Designs for Pelvic Organ Prolapse Repair

Title
Melt Electrowritten Biodegradable Mesh Implants with Auxetic Designs for Pelvic Organ Prolapse Repair
Type
Article in International Scientific Journal
Year
2025
Authors
Ferreira, NM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Antoniadi, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Silva, AT
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Parente, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fernandes, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Silva, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 15
Final page: 111
Publisher: MDPI
Other information
Authenticus ID: P-018-EVZ
Abstract (EN): <jats:p>Pelvic organ prolapse (POP) is a common condition among women, characterized by the descent of pelvic organs through the vaginal canal. Although traditional synthetic meshes are widely utilized, they are associated with complications such as erosion, infection, and tissue rejection. This study explores the design and fabrication of biodegradable auxetic implants using polycaprolactone and melt electrowriting technology, with the goal of developing implants that closely replicate the mechanical behavior of vaginal tissue while minimizing implant-related complications. Four distinct auxetic mesh geometries¿re-entrant Evans, Lozenge grid, square grid, and three-star honeycomb¿were fabricated with a 160 ¿m diameter and mechanically evaluated through uniaxial tensile testing. The results indicate that the square grid and three-star honeycomb geometries exhibit hyperelastic-like behavior, closely mimicking the stress¿strain response of vaginal tissue. The re-entrant Evans geometry has been observed to exhibit excessive stiffness for applications related to POP, primarily due to material overlap. This geometry demonstrates stiffness that is approximately five times greater than that of the square grid or the three-star honeycomb configurations, which contributes to an increase in local rigidity. The unique auxetic properties of these structures prevent the bundling effect observed in synthetic meshes, promoting improved load distribution and minimizing the risk of tissue compression. Additionally, increasing the extrusion diameter has been identified as a promising strategy for further refining the biomechanical properties of these meshes. These findings lay a solid foundation for the development of next-generation biodegradable implants.</jats:p>
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

INCONEL® Alloy Machining and Tool Wear Finite Element Analysis Assessment: An Extended Review (2024)
Another Publication in an International Scientific Journal
Pedroso, AFV; Sebbe, NPV; Costa, RDFS; Barbosa, MLS; Sales-Contini, RCM; Silva, FJG; Campilho, RDSG; Abilio M P De Jesus
Personalizing Industrial Maintenance Operation Using the Model of Hierarchical Complexity (2025)
Article in International Scientific Journal
Raposo, G; Araújo, N; Parente, M; António Mendes Lopes; Santos, A; Pereira, F; Leite, S; Ramos Silva, A
Numerical-Experimental Plastic-Damage Characterisation of Additively Manufactured 18Ni300 Maraging Steel by Means of Multiaxial Double-Notched Specimens (2021)
Article in International Scientific Journal
Tiago Silva; Afonso Gregório; Filipe Silva; José Xavier; Ana Reis; Pedro Rosa; Abílio M. P. de Jesus
Modelling the Heating Process in the Transient and Steady State of an In Situ Tape-Laying Machine Head (2022)
Article in International Scientific Journal
Rodrigues, JD; Goncalves, PT; Pina, L; Fernando Gomes Almeida
Comparison of Modulation-Assisted Machining Strategies for Achieving Chip Breakage When Turning 17-4 PH Stainless Steel (2024)
Article in International Scientific Journal
Ainhoa Robles; Asier Astarloa; Iñigo Llanos; Iker Mancisidor ; Fernandes MH; Jokin Munoa

See all (7)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-07-05 at 22:51:44 | Acceptable Use Policy | Data Protection Policy | Complaint Portal