Go to:
Logótipo
Você está em: Start > Publications > View > A fundamental data acquisition saving block
Map of Premises
Principal
Publication

A fundamental data acquisition saving block

Title
A fundamental data acquisition saving block
Type
Article in International Conference Proceedings Book
Year
2005
Authors
Loureiro, CFM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Martins, VMG
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Clemencio, FMC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Correia, CMBA
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 685-686
Nuclear Science Symposium/Medical Imaging Conference
Fajardo, PR, OCT 23-29, 2005
Other information
Authenticus ID: P-000-72E
Abstract (EN): A general data acquisition architecture, allowing a clean conceptual separation of the fundamental blocks in a data acquisition setup, is presented. The approach taken surfaced from a study of several modern architectures and from experience acquired while developing an object-oriented programming solution for a previously developed high-speed architecture. This process of software development leaded naturally to a concept where a net separation between data transfer, and control and trigger signals, suggested a similar general decomposition of the data acquisition hardware, in such a way that the same fundamental hardware blocks can be used in several different configurations. In this paper we report on the strategy and results obtained while developing in VHDL such an important and fundamental unit of the data acquisition chain as the data acquisition saving block. The solution proposed for the data saving block, tested using field programmable gate arrays, implements pre- and post-trigger functionality, supports continuous data streams up to hundreds of MHz, has a large memory pool (hundreds of megabytes), and has an interface capable of providing, upon request, a block of data from a specified address without interfering with the data saving process.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 2
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Medicina Dentária da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z