Saltar para:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Início > Publicações > Visualização > Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent
Mapa das Instalações
Edifício Principal | Main Building Edifício Pós-Graduações | Post-Graduate Building

Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent

Título
Microgap and microleakage of a hybrid connection platform-switched implant system in the absence or presence of a silicone-based sealing agent
Tipo
Artigo em Revista Científica Internacional
Ano
2021
Autores
Revista
Título: ODONTOLOGYImportada do Authenticus Pesquisar Publicações da Revista
ISSN: 1618-1247
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Publicação em ISI Web of Science ISI Web of Science
Publicação em Scopus Scopus
Pubmed / Medline
Outras Informações
ID Authenticus: P-00V-BZV
Abstract (EN): The present study aims to characterize, for the first time, the microgap and bacterial microleakage of a platform-switched implant system with hybrid connection, screwed at distinct torque values (manufacturer recommended torque-25 N cm-and a reduced torque-5 N cm-mimicking the long-term functional use), in the absence or presence of a silicon-based sealing agent. Microgap was determined through scanning electron microscopy and bacterial microleakage was evaluated in vitro, upon Enterococcus faecalis colonization of the system. The sealing efficacy was evaluated in the absence or presence of a commercially available silicon-based sealer. The cytotoxicity of the sealer was further addressed in vitro, with a fibroblastic cell line, in accordance with reference standards. A low microgap of the implant system was verified, regardless of the applied torque load-maximal values ranged around 0.25 and 1.25 mu m, for 25 and 5 N cm torques, respectively. No bacterial microleakage was reported at 25 N cm, while at 5 N cm, leakage was verified on 38% of the samples. The application of a silicon-based sealer-with an adequate cytocompatible profile-was effective on preventing the bacterial microleakage on the assayed experimental setting. The assayed platform-switched implant system with hybrid connection presented a low interfacial misfit and an effective sealing capability at manufacturer recommended torque. Despite the increased microleakage at low torque conditions, the application of a cytocompatible silicon-based sealing agent restored the sealing effectiveness of the system. The use of a silicon-based sealing agent can assist on the maintenance of the sealing effectiveness even at low torque conditions.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 9
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Dos mesmos autores

Microgap and bacterial microleakage during the osseointegration period: An in vitro assessment of the cover screw and healing abutment in a platform-switched implant system (2021)
Artigo em Revista Científica Internacional
Pedro Ferrás da Silva Fernandes; Liliana Grenho; Fernandes MH; Sampaio-Fernandes J.; Gomes PS
Recomendar Página Voltar ao Topo
Copyright 1996-2024 © Faculdade de Economia da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z  I Livro de Visitas
Página gerada em: 2024-09-29 às 02:27:54 | Política de Utilização Aceitável | Política de Proteção de Dados Pessoais | Denúncias
SAMA2