Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Calibration of bi-planar radiography with minimal phantoms
Publication

Calibration of bi-planar radiography with minimal phantoms

Title
Calibration of bi-planar radiography with minimal phantoms
Type
Article in International Conference Proceedings Book
Year
2008
Authors
Daniel Cardoso de Moura
(Author)
FEUP
Jorge Manuel Gomes Barbosa
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
João Manuel Ribeiro da Silva Tavares
(Author)
FEUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Ana Reis
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings National
Initial page: 10 pag.
DSIE'08 - Doctoral Symposium on Informatics Engineering 2008
Faculdade de Engenharia da Universidade do Porto, Porto, Portugal, 7/8 February 2008
Scientific classification
FOS: Engineering and technology > Other engineering and technologies
CORDIS: Technological sciences > Engineering > Biomedical enginnering ; Technological sciences > Technology > Computer technology > Image processing
Other information
Abstract (EN): In this paper we propose a method for the geometrical calibration of bi-planar radiography that aims at minimising the impact of calibration phantoms on the content of radiographs. These phantoms are required for determining scale or to estimate the geometrical parameters of the system. Unfortunately, they often overlap anatomical structures. For accomplishing this goal, we propose a small extension to conventional imaging systems: a distance measuring device that enables to estimate some of the geometrical parameters. This leads to a reduction of the search space of solutions, which makes possible reducing requirements of calibration phantoms. The proposed method was tested on 17 pairs of radiographs of a phantom object of known dimensions. For calculating scale, only a reference distance of 40mm was used. Results show a RMS error of 0.36mm with 99% of the errors inferior to 0.85mm. Additionally, the requirements of the calibration phantom are very low when compared with other methods, but experiments with anatomical structures should be conducted to confirm these results.
Language: English
Type (Professor's evaluation): Scientific
Contact: www.fe.up.pt/~tavares
No. of pages: 10
License type: Click to view license CC BY-NC
Documents
File name Description Size
Calibration of bi-planar radiography with minimal phantoms 1204.97 KB
Related Publications

Of the same scientific areas

Semiautomated ultrasonographic measurement of fetal nuchal translucency using a computer software tool (1997)
Article in International Scientific Journal
F. Bernardino; R. Cardoso; N. Montenegro; João Bernardes; Joaquim Pontes Marques de Sá
Acquisition and analysis of 3D mandibular movement using a device based on electromagnetic sensors and a neural network (2009)
Article in International Scientific Journal
Isa C. T. Santos; J. M. R. S. TAVARES; J. G. MENDES; M. P. F. PAULO
Magnetic resonance imaging of the vocal tract: techniques and applications (2009)
Article in International Conference Proceedings Book
Sandra M. Rua Ventura ; Diamantino Freitas; João Manuel R. S. Tavares
Aesthetic evaluation of conservative breast cancer treatment : can measuring help? (2004)
Article in International Conference Proceedings Book
Maria Cardoso; I. Leitao; A Moura; Ana Santos; Jaime dos Santos Cardoso; Henrique Barros; M. Oliveira
A novel method to automatically segment the pelvic floor muscles in MR images (2009)
Article in International Conference Proceedings Book
Zhen Ma; João Manuel R. S.Tavares; Renato Natal M. Jorge
Recommend this page Top
Copyright 1996-2024 © Faculdade de Economia da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-08-16 at 13:24:36 | Acceptable Use Policy | Data Protection Policy | Complaint Portal
SAMA2