Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Accuracy and temporal analysis of non-Newtonian models of blood in the computational FFR - Numerical implementation
Publication

Accuracy and temporal analysis of non-Newtonian models of blood in the computational FFR - Numerical implementation

Title
Accuracy and temporal analysis of non-Newtonian models of blood in the computational FFR - Numerical implementation
Type
Article in International Scientific Journal
Year
2024
Authors
Fernandes, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Sousa, LC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pinto, SIS
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 161
ISSN: 0020-7462
Publisher: Elsevier
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-010-0MH
Abstract (EN): Non-invasive assessment of stenosed coronary is a goal for clinical applications. Thus, engineering aligned with medicine has been the solution to solve this problem. This work, serving as a proof of concept, has the main goal to predict the non-invasive fractional flow reserve (FFR) in an atherosclerotic coronary artery. A 3 -element Windkessel and Womersley models were used to model boundary conditions of the patient-specific coronary arteries: the pressure at the outlets of the artery and the velocity at the inlet, respectively. Apart from implementing the previous conditions in the numerical code, the novelty of this work is to implement and use, in numerical simulations, Newtonian and non-Newtonian models for blood such as Carreau, Carreau-Yasuda, Casson and Simplified Phan-Thien/Tanner to analyse the accuracy of the computed FFR and the computational time of the simulations. Results indicate that the non-Newtonian viscoelastic model, Simplified PhanThien/Tanner, took the longest time but produced the most accurate results - 8h and 2.7% relative error between invasive and non-invasive FFR. The shear-thinning non-Newtonian models required lower computational times but returned a higher average error (3.9h; 7.6% error) which is considered significant. The Newtonian model required the least time but had the highest error value (2.9h; 7.8% error). Thus, although the computational time considering the non-Newtonian viscoelastic model is the highest, this model must be considered in the numerical simulations to obtain the FFR since it is the most accurate for this patient case. This research is a step forward to numerically quantify the non-invasive FFR of a patient.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 11
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Non-Linear Dynamics of Micro- and Nano- Electro-Mechanical Systems (2020)
Another Publication in an International Scientific Journal
Pedro Leal Ribeiro; Stefano Lenci; Sondipon Adhikari
The impact of non-linear viscoelastic property of blood in right coronary arteries hemodynamics - A numerical implementation (2020)
Article in International Scientific Journal
Sónia Isabel S. Pinto; Ernesto Romano; Carlos Alberto Conceição António; Luísa Costa Sousa; Catarina Castro
Panel flutter suppression with nonlinear energy sinks: Numerical modeling and analysis (2018)
Article in International Scientific Journal
Douglas R. Q. Pacheco; Flávio D. Marques; António J. M. Ferreira
Non-linear vibrations of beams with non-symmetrical cross sections (2013)
Article in International Scientific Journal
S. Stoykov; P. Ribeiro

See all (8)

Recommend this page Top
Copyright 1996-2024 © Faculdade de Economia da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2024-07-17 at 21:18:21 | Acceptable Use Policy | Data Protection Policy | Complaint Portal
SAMA2