Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Development of an HPLC-UV method for determination of taurine in infant formulae and breast milk
Publication

Development of an HPLC-UV method for determination of taurine in infant formulae and breast milk

Title
Development of an HPLC-UV method for determination of taurine in infant formulae and breast milk
Type
Article in International Scientific Journal
Year
1997
Authors
Ferreira, IMPLVO
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Nunes, MV
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Mendes, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Remiao, F
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Ferreira, MA
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 20
Pages: 1269-1278
ISSN: 1082-6076
Publisher: Taylor & Francis
Scientific classification
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-001-CP8
Abstract (EN): A rapid and accurate high performance liquid chromatographic (HPLC) procedure was proposed for routine and selective determination of taurine in infant formulas and breast milk. The sample preparation was simple, involving protein removal and filtration operations. Afterwards, taurine,was derivatised with o-phthalaldehyde/2-mercaptoethanol prior to injection onto a reversed phase column C-18 (S10ODS2). Isocratic elution was carried out using 0.05 M phosphate buffer pH 5.3/methanol (60:40) mixture. The effluent was monitored by a UV detector at 350 nm. A linear relationship was found between peak area and a concentration range of 1-70 mu g/mL. The detection limit was 0.3 mu g/mL. Effective separation and quantification was achieved in under six: minutes. No interference of other amino acids was observed.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 10
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Validation of a Micromethod for Quantification of Lutein and β-Carotene in Olive Oil (2008)
Article in International Scientific Journal
Lúcia Maia ; Susana Casal; M. Beatriz P. P. Oliveira
Validation of a micromethod for quantification of lutein and beta-carotene in olive oil (2008)
Article in International Scientific Journal
Lúcia Maia; Susana Casal; M. Beatriz Oliveira; Paula Oliveira
Simultaneous determination of sugars, uric and orotic acids in infant formulae by HPLC-UV/RI (1997)
Article in International Scientific Journal
Ferreira, IMPLVO; Ferreira, MA
Simultaneous determination of flavonoids, phenolic acids, and coumarins in seven medicinal species by HPLC/diode-array detector (1998)
Article in International Scientific Journal
Andrade, PB; Seabra, RM; Valentao, P; Areias, F

See all (36)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Economia da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z  I Guest Book
Page created on: 2025-06-23 at 21:18:54 | Acceptable Use Policy | Data Protection Policy | Complaint Portal
SAMA2