Lab-on-Valve Automated and Miniaturized Assessment of Nanoparticle Concentration Based on Light-Scattering

Título
Lab-on-Valve Automated and Miniaturized Assessment of Nanoparticle Concentration Based on Light-Scattering
Tipo
Artigo em Revista Científica Internacional
Ano
2023
Autores
Marques, SS
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Ramos, II
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Silva, C
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Domingues, MR
(Autor)
Outra
A pessoa não pertence à instituição. A pessoa não pertence à instituição. A pessoa não pertence à instituição. Sem AUTHENTICUS Sem ORCID
Marcela A Segundo
(Autor)
FFUP
Ver página pessoal Sem permissões para visualizar e-mail institucional Pesquisar Publicações do Participante Ver página do Authenticus Sem ORCID
Revista
Título: Analytical ChemistryImportada do Authenticus Pesquisar Publicações da Revista
Vol. 95
Páginas: 4619-4626
ISSN: 0003-2700
Indexação
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citações
Outras Informações
ID Authenticus: P-00Y-02Z
Abstract (EN): Nanoparticles (NPs) concentration directly impacts the dose delivered to target tissues by nanocarriers. The evaluation of this parameter is required during NPs developmental and quality control stages, for setting dose-response correlations and for evaluating the reproduci-bility of the manufacturing process. Still, faster and simpler procedures, dismissing skilled operators and post-analysis conversions are needed to quantify NPs for research and quality control operations, and to support result validation. Herein, a miniaturized automated ensemble method to measure NPs concentration was established under the lab-on-valve (LOV) mesofluidic platform. Automatic NPs sampling and delivery to the LOV detection unit were set by flow programming. NPs concentration measurements were based on the decrease in the light transmitted to the detector due to the light scattered by NPs when passing through the optical path. Each analysis was accomplished in 2 min, rendering a determination throughput of 30 h-1 (6 samples h-1 for n = 5) and only requiring 30 mu L (approximate to 0.03 g) of NPs suspension. Measurements were performed on polymeric NPs, as these represent one of the major classes of NPs under development for drug-delivery aims. Determinations for polystyrene NPs (of 100, 200, and 500 nm) and for NPs made of PEGylated poly-D,L-lactide-co- glycolide (PEG-PLGA, a biocompatible FDA-approved polymer) were accomplished within 108-1012 particles mL-1 range, depending on the NPs size and composition. NPs size and concentration were maintained during analysis, as verified for NPs eluted from the LOV by particle tracking analysis (PTA). Moreover, concentration measurements for PEG-PLGA NPs loaded with an anti-inflammatory drug, methotrexate (MTX), after their incubation in simulated gastric and intestinal fluids were successfully achieved (recovery values of 102-115%, as confirmed by PTA), showing the suitability of the proposed method to support the development of polymeric NPs targeting intestinal delivery.
Idioma: Inglês
Tipo (Avaliação Docente): Científica
Nº de páginas: 8
Documentos
Não foi encontrado nenhum documento associado à publicação.
Publicações Relacionadas

Da mesma revista

Voltammetric Studies of Topotecan Transfer Across Liquid/Liquid Interfaces and Sensing Applications (2015)
Artigo em Revista Científica Internacional
Kim, HR; Carlos M Pereira; Han, HY; Lee, HJ
Unbreakable solid-phase microextraction fibers obtained by sol-gel deposition on titanium wire (2006)
Artigo em Revista Científica Internacional
Azenha, MA; Nogueira, PJ; Silva, AF
Subppm Amine Detection via Absorption and Luminescence Turn-On Caused by Ligand Exchange in Metal Organic Frameworks (2019)
Artigo em Revista Científica Internacional
Sousaraei, A; Queiros, C; Moscoso, FG; Tania, C; Pedrosa, JM; Silva, AMG; Cunha Silva, L; Cabanillas Gonzalez, J
Recent Advances on Mass Spectrometry Analysis of Nitrated Phospholipids (2016)
Artigo em Revista Científica Internacional
Melo, T; Domingues, P; Ferreira, R; Milic, I; Fedorova, M; Santos, SM; Marcela A Segundo; Domingues, MRM

Ver todas (21)

Recomendar Página Voltar ao Topo
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Termos e Condições  I Acessibilidade  I Índice A-Z
Página gerada em: 2025-11-14 às 22:11:21 | Política de Privacidade | Política de Proteção de Dados Pessoais | Denúncias | Livro Amarelo Eletrónico