Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > FLOW-THROUGH TUBULAR IODIDE AND BROMIDE SELECTIVE ELECTRODES BASED ON EPOXY-RESIN HETEROGENEOUS MEMBRANES
Publication

Publications

FLOW-THROUGH TUBULAR IODIDE AND BROMIDE SELECTIVE ELECTRODES BASED ON EPOXY-RESIN HETEROGENEOUS MEMBRANES

Title
FLOW-THROUGH TUBULAR IODIDE AND BROMIDE SELECTIVE ELECTRODES BASED ON EPOXY-RESIN HETEROGENEOUS MEMBRANES
Type
Article in International Scientific Journal
Year
1989
Authors
alegret, s
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
florido, a
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
machado, aasc
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: TalantaImported from Authenticus Search for Journal Publications
Vol. 36
Pages: 825-829
ISSN: 0039-9140
Publisher: Elsevier
Scientific classification
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-001-SHF
Abstract (EN): Tubular all-solid-state iodide and bromide selective electrodes with channels drilled through the crystalline heterogeneous membranes have been prepared for use in flow-injection analysis (FIA). The membranes, made with AgX/Ag2S powdered mixtures (X = I, Br) dispersed in a non-conductive epoxy resin, were assembled inside a hollow cylindrical support of conductive epoxy resin. The response characteristics of these detectors, in a low-dispersion FIA system, have been evaluated. Both show a Nernstian response over the range between 5 × 10-5 and O.1M X-, good reproducibility and fast response, which allows a sampling rate of 60/hr. Operational pH ranges from 2.5 to 11 and from 3 to 10 were obtained for the iodide and bromide electrodes respectively. Iodide must be absent in determinations with the bromide electrode. © 1989.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Recent developments, characteristics and potential applications of screen-printed electrodes in pharmaceutical and biological analysis (2016)
Another Publication in an International Scientific Journal
Couto, RAS; Lima, JLFC; M. Beatriz Q. Garcia
Optical sensors and biosensors based on sol-gel films (2007)
Another Publication in an International Scientific Journal
Paula C A Jeronimo; Alberto N Araujo; Conceicao C B S M Montenegro
Flow injection based methods for fast screening of antioxidant capacity (2009)
Another Publication in an International Scientific Journal
Luis M Magalhaes; Miguel Santos; Marcela A Segundo; Salette Reis; Jose L F C Lima
Extraction and preconcentration techniques for chromatographic determination of chlorophenols in environmental and food samples (2012)
Another Publication in an International Scientific Journal
Paulo de Morais; Teodor Stoichev; Clara C P Basto; Teresa T S D Vasconcelos

See all (193)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-07 at 17:21:05 | Privacy Policy | Personal Data Protection Policy | Whistleblowing