Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Automatic multilead VCG based approach for QT interval measurement
Publication

Publications

Automatic multilead VCG based approach for QT interval measurement

Title
Automatic multilead VCG based approach for QT interval measurement
Type
Article in International Conference Proceedings Book
Year
2006
Authors
Martinez, JP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rocha, AP
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Olmos, S
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Laguna, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 369-372
2006 Computers in Cardiology, CIC
Valencia, 17 September 2006 through 20 September 2006
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge
Other information
Authenticus ID: P-007-N12
Abstract (EN): The precision of QT interval measures depends on the correct location of QRS and T boundaries and also on the analysing lead. The usual automatic strategy to deal with multiple leads is to apply post-processing decision rules for selecting one of the single-lead (SL) measures. We proposed a multilead VCG strategy that locates the onset and the end of the QT interval, attending to an optimal transformed lead according to the spatial characteristics of the VCG. The performance was evaluated over the CSE database considering different VCG systems: corrected Frank system (lead set F), pseudo-orthogonal leads V5, aVF and V2 (M) and the X, Y and Z leads derived by Dower transformation (D). Multilead delineation over F achieved a better results than any single lead by itself or any other lead set, with an error dispersion similar to SL over 12 leads plus decision rules. The multilead approach is validated in the PTB database, in the Physionet/CinC Challenge 2006, with final scores of 27.04, 27.81 and 28.96, over F, M and D, respectively.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

A wavelet-based ECG delineator: Evaluation on standard databases (2004)
Article in International Scientific Journal
Martinez, JP; Almeida, R; Olmos, S; Rocha, AP; Laguna, P
Improved QT variability quantification by multilead automatic delineation (2005)
Article in International Conference Proceedings Book
Almeida, R; Martinez, JP; Rocha, AP; Olmos, S; Laguna, P
A parametric model approach for quantification of short term QT variability uncorrelated with heart rate variability (2003)
Article in International Conference Proceedings Book
Almeida, R; Pueyo, E; Martinez, JP; Rocha, AP; Olmos, S; Laguna, P
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-25 at 06:18:17 | Privacy Policy | Personal Data Protection Policy | Whistleblowing