Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Are 2 Electrocardiographic Leads Enough for Multilead Wave Boundary Location and QT Measuring?
Publication

Publications

Are 2 Electrocardiographic Leads Enough for Multilead Wave Boundary Location and QT Measuring?

Title
Are 2 Electrocardiographic Leads Enough for Multilead Wave Boundary Location and QT Measuring?
Type
Article in International Conference Proceedings Book
Year
2009
Authors
Martinez, JP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Rocha, AP
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Laguna, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 593-596
36th Annual Computers in Cardiology Conference (CinC 2009)
Pk City, UT, SEP 13-16, 2009
Scientific classification
FOS: Engineering and technology > Environmental biotechnology
Other information
Authenticus ID: P-005-6ZQ
Abstract (EN): Different latencies on the cardiac electric phenomena can be found across leads. Thus combining adequately the information provided by multiple leads is essential for the correct location of global wave boundaries. A multilead-VCG strategy for boundaries location, by constructing a transformed spatial lead obtained from 3 orthogonal leads and optimized for delineation improvement, has been previously proposed and validated I I I. The goal of this work was to study and to quantify the performance loss when just 2 orthogonal leads are used. Combination of 2 leads were considered, both using recorded Frank leads, leads synthesised using inverse Dower transformation, and principal component analysis. The errors in QRS onset and T wave end location and in QT interval measurement were evaluated over the PTB database files. Results indicate that 2 leads properly selected are enough to locate QRS onset but possibly not for T wave end.
Language: English
Type (Professor's evaluation): Scientific
Contact: rbalmeid@unizar.es
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

QT variability and HRV interactions in ECG: Quantification and reliability (2006)
Article in International Scientific Journal
Almeida, R; Gouveia, S; Rocha, AP; Pueyo, E; Martinez, JP; Laguna, P
A wavelet-based ECG delineator: Evaluation on standard databases (2004)
Article in International Scientific Journal
Martinez, JP; Almeida, R; Olmos, S; Rocha, AP; Laguna, P
Quantification of the QT variability related to HRV: Robustness study facing automatic delineation and noise on the ECG (2004)
Article in International Conference Proceedings Book
Almeida, R; Pueyo, E; Martinez, JP; Rocha, AP; Laguna, P
P Wave Delineation Using Spatially Projected Leads From Wavelet Transform Loops (2010)
Article in International Conference Proceedings Book
Almeida, R; Martinez, JP; Rocha, AP; Laguna, P
Improved QT variability quantification by multilead automatic delineation (2005)
Article in International Conference Proceedings Book
Almeida, R; Martinez, JP; Rocha, AP; Olmos, S; Laguna, P

See all (7)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-09-05 at 17:43:37 | Privacy Policy | Personal Data Protection Policy | Whistleblowing