Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Simple stochastic fingerprints towards mathematical modeling in biology and medicine. 3. Ocular irritability classification model
Publication

Publications

Simple stochastic fingerprints towards mathematical modeling in biology and medicine. 3. Ocular irritability classification model

Title
Simple stochastic fingerprints towards mathematical modeling in biology and medicine. 3. Ocular irritability classification model
Type
Article in International Scientific Journal
Year
2006
Authors
cruz-monteagudo, maykel
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
gonzalez-diaz, humberto
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
borges, fernanda
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
gonzalez-diaz, yenny
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Vol. 68
Pages: 1555-1572
ISSN: 0092-8240
Publisher: Springer Nature
Scientific classification
FOS: Natural sciences > Chemical sciences
CORDIS: Physical sciences > Chemistry
Other information
Authenticus ID: P-004-GQ8
Abstract (EN): MARCH-INSIDE methodology and a statistical classification method-linear discriminant analysis (LDA)-is proposed as an alternative method to the Draize eye irritation test. This methodology has been successfully applied to a set of 46 neutral organic chemicals, which have been defined as ocular irritant or nonirritant. The model allow to categorize correctly 37 out of 46 compounds, showing an accuracy of 80.46%. Specifically, this model demonstrates the existence of a good categorization average of 91.67 and 76.47% for irritant and nonirritant compounds, respectively. Validation of the model was carried out using two cross-validation tools: Leave-one-out (LOO) and leave-group-out (LGO), showing a global predictability of the model of 71.7 and 70%, respectively. The average of coincidence of the predictions between leave-one-out/leave-group-out studies and train set were 91.3% (42 out of 46 cases)/89.1% (41 out of 46 cases) proving the robustness of the model obtained. Ocular irritancy distribution diagram is carried out in order to determine the intervals of the property where the probability of finding an irritant compound is maximal relating to the choice of find a false nonirritant one. It seems that, until today, the present model may be the first predictive linear discriminant equation able to discriminate between eye irritant and nonirritant chemicals.
Language: English
Type (Professor's evaluation): Scientific
Contact: gonzalezdiazh@yahoo.es
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-13 at 15:47:59 | Privacy Policy | Personal Data Protection Policy | Whistleblowing