Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Optimization of a bipotentiometric flow injection analysis system for simultaneous determination of calcium and chloride ions in natural waters
Publication

Publications

Optimization of a bipotentiometric flow injection analysis system for simultaneous determination of calcium and chloride ions in natural waters

Title
Optimization of a bipotentiometric flow injection analysis system for simultaneous determination of calcium and chloride ions in natural waters
Type
Article in International Scientific Journal
Year
1998
Authors
Machado, AASC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: The AnalystImported from Authenticus Search for Journal Publications
Vol. 123
Pages: 653-659
ISSN: 0003-2654
Scientific classification
FOS: Natural sciences > Chemical sciences
Other information
Authenticus ID: P-001-84V
Abstract (EN): The experimental optimization by the modified simplex method of a bipotentiometric flow injection analysis (FIA) system, constituted by two different ion selective electrodes (ISEs) placed in series, for the simultaneous determination of calcium and chloride in waters is reported. The response function used was a weighted linear combination of three variables, chosen to achieve maximization of the calcium electrode sensitivity, minimization of the interference of the calcium signal on the chloride response and maximization of the sampling rate. The optimized system is able to determine calcium in the range 5 x 10(-5)-5 x 10(-3) mol l(-1) with a sensitivity of ca, 27 mV decade(-1) and chloride in the range 2 x 10(-4)-2 x 10(-2) mol l(-1), the maximum value tested, with a sensitivity of ca, 55 mV decade(-1). The repeatability found was 1.9 and 0.6%, respectively, at 2 x 10(-4) and 2.2 x 10(-3) mol l(-1) (8 and 90 mg l(-1)), for calcium determinations, and 1.8 and 1.2%, respectively, at 3.4 x 10(-4) and 8.3 x 10(-4) mol l(-1) (12 and 29 mg l(-1)), for chloride determinations. A sampling rate of 40 h(-1) was obtained, The influence of the ionic strength on the results is discussed. The relative accuracy of the bipotentiometric: FIA system was demonstrated by determination of the contents of both ions in natural waters in parallel with ASTM certified methods.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Usefulness of a ruggedness test in the validation of flow injection analysis systems (1997)
Article in International Scientific Journal
Alvares Ribeiro, LMBC; Machado, AASC
COMPARISON OF THE SIMPLEX AND POWELL METHODS WITH A WEIGHTED RESPONSE FUNCTION FOR THE OPTIMIZATION OF FIA SYSTEMS (1993)
Article in International Scientific Journal
ALVARESRIBEIRO, LMBC; MACHADO, AASC; ALONSO, J; BARTROLI, J; DELVALLE, M

Of the same journal

The role of ionic liquids in the biocatalytic evaluation of bisphenol levels as contaminant: an automatic approach (2018)
Article in International Scientific Journal
Costa, AR; Passos, MLC; Pinto, PCAG; Pereira, SAP; Lucia L M F S Saraiva
Stochastic detection and characterisation of individual ferrocene derivative tagged graphene nanoplatelets (2016)
Article in International Scientific Journal
Wu, HY; Lin, QW; Batchelor McAuley, C; Goncalves, LM; Lima, CFRAC; Compton, RG

See all (47)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-06 at 12:59:34 | Privacy Policy | Personal Data Protection Policy | Whistleblowing