Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Pulmonary function electronic monitoring devices - A randomized agreement study
Publication

Publications

Pulmonary function electronic monitoring devices - A randomized agreement study

Title
Pulmonary function electronic monitoring devices - A randomized agreement study
Type
Article in International Scientific Journal
Year
2005
Authors
Delgado, L
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Silva, LN
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Magalhaes, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Castel Branco, MG
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Vaz, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: ChestImported from Authenticus Search for Journal Publications
Vol. 128
Pages: 1258-1265
ISSN: 0012-3692
Publisher: Elsevier
Other information
Authenticus ID: P-000-1FH
Abstract (EN): Study objectives: To compare in a clinical setting the within-session reproducibility, of two pulmonary function electronic monitoring devices (PiKo-1; Ferraris Respiratory Europe; Hereford, UK; and Spirotel; MIR; Rome, Italy) with one mechanical device (Mini-Wright Peak-Flow Meter; Clement-Clarke International; Harlow, Essex, UK), and to evaluate the accuracy of these devices using as reference an office pneumotachograph. Design, setting, and participants: After detailed instructions, adults without airways diseases and patients with stable asthma attending an outpatient clinic performed four sets of expiratory maneuvers, one set for each device, in a strictly, random order. Each set comprised three maneuvers with 2 to 3 min of rest between them. Measurements: Reproducibility of FEV1 and peak expiratory, flow (PEF) was assessed by a coefficient of variation (CV) and intraclass correlation coefficient (ICC), and accuracy was assessed by ICC and limits of agreement. Results: Of the 38 participants evaluated, 71% were women and 61% had asthma. Ages ranged from 18 to 58 years, and FEV1 ranged from 1.2 to 4.8 L. In all monitoring devices, CV was < 6% and ICC was > 0.94 for the reproducibility of both FEV, and PEF measurements. The accuracy of the PiKo-1 device was better for FEV, (ICC = 0.98) than for PEF (ICC = 0.90). The Spirotel device had similar results for FEV, and PEF (ICC = 0.95). The Mini-Wright device had the lowest accuracy (ICC = 0.87), particularly for PEF values < 500 L/min. Conclusions: These low-cost and easy-to-use electronic monitoring devices showed a very good reproducibility and were in agreement with the pneumotachograph. Therefore, the PiKo-I and Spirotel devices seem adequate for both screening and monitoring. However, prospective studies are still needed to assess their long-term reproducibility and usability and, particularly, the effects on the improvement of respiratory, care.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

International conference for the development of consensus on the diagnosis and treatment of ventilator-associated pneumonia (2001)
Another Publication in an International Scientific Journal
Rello, J; Paiva, J-A; Baraibar, J; Barcenilla, F; Bodi, M; Castander, D; Correa, H; Diaz, E; Garnacho, J; Llorio, M; Rios, M; Rodriguez, A; Sole Violan, J
HUGHES-STOVIN SYNDROME WITH PULMONARY ANGIITIS AND FOCAL GLOMERULONEPHRITIS - A CASE-REPORT WITH NECROPSY STUDY (1981)
Another Publication in an International Scientific Journal
MEIRELES, A; Sobrinho Simoes, M; CAPUCHO, R; BRANDAO, A
Heat it or wet it? Nasal symptoms secondary to the use of continuous positive airway pressure in sleep apnea (2001)
Another Publication in an International Scientific Journal
Winck, JC; Delgado, L; Fonseca, J; Marques JA; Fleury, B
THE VALUE OF FLEXIBLE BRONCHOSCOPY IN CHILDHOOD PULMONARY TUBERCULOSIS (1991)
Article in International Scientific Journal
DEBLIC, J; Inês Azevedo; BURREN, CP; LEBOURGEOIS, M; LALLEMAND, D; SCHEINMANN, P

See all (8)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-09 at 04:33:48 | Privacy Policy | Personal Data Protection Policy | Whistleblowing