Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Validação do método de determinação simultânea dos íons brometo e bromato por cromatografia iônica em águas de consumo humano
Publication

Publications

Validação do método de determinação simultânea dos íons brometo e bromato por cromatografia iônica em águas de consumo humano

Title
Validação do método de determinação simultânea dos íons brometo e bromato por cromatografia iônica em águas de consumo humano
Type
Article in International Scientific Journal
Year
2004
Authors
Gonçalves, MEP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Camões, MF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Benoliel, MJ
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Carneiro, RN
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: Quimica NovaImported from Authenticus Search for Journal Publications
Vol. 27
Pages: 503-507
ISSN: 0100-4042
Other information
Authenticus ID: P-00J-VDB
Abstract (EN): VALIDATION OF SIMULTANEOUS DETERMINATION OF BROMIDES AND BROMATES BY ION CHROMATOGRAPHY IN DRINKING WATER. European Directive (98/83/CE), compulsory after 2008, states that bromate in drinking water must be controlled at levels below 10 mg L-1. Supporting implementation of the Directive, the European Comission has established project SMT4-CT96 2134, in collaboration with various european institutions, aiming at the identification of the interferents to the current analytical method (Ionic Chromatography with Conductimetric Detection - IC/CD), their removal and the automation of pretreatment and injection steps, as well as the development of alternative methods. EPAL, responsible for the water supply to a great deal of Portuguese regions, has taken steps to meet these requirements. Although not part of such project, this work (the result of a project conducted under a protocol of collaboration between EPAL SA and FOUL - Faculty of Sciences, University of Lisbon), reports on studies of usefulness to laboratories planning to monitor bromate in ozone treated waters, in conditions different from those described in EPA 300.1. Simultaneous determination of bromide is justified by its role as bromate precursor.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

SOLID LIPID NANOPARTICLES: CLASSICAL METHODS OF LAB PRODUCTION (2011)
Another Publication in an International Scientific Journal
Souto, EB; Severino, P; Santana, MHA; Pinho, SC
Potentiometric detectors for flow injection analysis systems, evolution and application. (2000)
Another Publication in an International Scientific Journal
Couto, CMCM; Montenegro, MCBSM
HYDROGEN PRODUCTION BY ALKALINE WATER ELECTROLYSIS (2013)
Another Publication in an International Scientific Journal
Sequeira, CAC; José Luis Figueiredo
HEALTH BENEFITS OF COFFEE: MYTH OR REALITY? (2009)
Another Publication in an International Scientific Journal
Rita C Alves; Susana Casal; Beatriz Oliveira

See all (45)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-24 at 17:23:16 | Privacy Policy | Personal Data Protection Policy | Whistleblowing