Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > The HIA MCAO laboratory bench
Publication

Publications

The HIA MCAO laboratory bench

Title
The HIA MCAO laboratory bench
Type
Article in International Conference Proceedings Book
Year
2012
Authors
Véran, JP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
McWeigh, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Andersen, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Correia, C
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Herriot, G
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pazder, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Other information
Authenticus ID: P-00H-XM0
Abstract (EN): This paper presents an update on the design and deployment of the HIA MCAO laboratory bench. This bench directly supports the development of NFIRAOS, the first light MCAO facility for the Thirty Meter Telescope. The bench implements a closed-loop MCAO system, with two magnetic DMs, four LGS Shack-Hartmann WFSs, two NGS T/T WFS, one NGS T/T/F WFS and one higher order Truth WFS, making up a scaled down version of NFIRAOS. The bench includes several artificial turbulence screens and reproduces realistic LGS spot elongations. It is driven by software in Matlab, frame-rates ranging from 1Hz to 15Hz. The goals of this bench are to anchor the NFIRAOS end-to-end simulation tools; to exercise real-time LGS tomographic AO in a variety of well controlled conditions, such as faint and poorly corrected NGSs, non-uniformities in the sodium layer and field dependant Non-Common-Path Aberrations (NCPAs); develop and demonstrate calibration procedures, such as PSF reconstruction and tomographic reconstruction and correction of field dependant NCPAs; and to validate optimization methods that operate at 10+ second time scales, which is not tractable in a numerical simulation, such as matched filter update and Cn2 estimation using a SLODAR method. © 2012 SPIE.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 12
Documents
We could not find any documents associated to the publication.