Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > PPG-Based Real-Time Blood Pressure Monitoring using Reflective Pulse Transit Time: Rest vs. Exercise Evaluation
Publication

Publications

PPG-Based Real-Time Blood Pressure Monitoring using Reflective Pulse Transit Time: Rest vs. Exercise Evaluation

Title
PPG-Based Real-Time Blood Pressure Monitoring using Reflective Pulse Transit Time: Rest vs. Exercise Evaluation
Type
Article in International Conference Proceedings Book
Year
2024
Authors
Aslani, R
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Dias, D
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Conference proceedings International
Pages: 1084-1088
IEEE 22nd Mediterranean Electrotechnical Conference (MELECON)
Porto, PORTUGAL, JUN 25-27, 2024
Indexing
Publicação em ISI Web of Knowledge ISI Web of Knowledge - 0 Citations
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-016-W3G
Abstract (EN): Direct blood pressure (BP) measurements require cuff compression, which not only is time-consuming but also inconvenient for frequent monitoring. This study addresses the challenge of continuous BP estimation (both Systolic (SBP) and Diastolic (DBP)) during exercise in a cuff-less manner, utilizing photoplethysmography (PPG) signals acquired by low-cost wearables. Leveraging Reflective Pulse-wave Transit Time (R-PTT), state-of-the-art algorithms were put to the test in two datasets (total subjects = 18). DATASET1 contains PPG signal and BP measurements of subjects in resting state, while DATASET2 comprises data of subjects in resting state and during exercise. The results reveal competitive performance, with Mean Absolute Error (MAE) of the estimation algorithm for DATASET1 being SBP=7.9 mmHg and DBP=5.2 mmHg and SBP=14.4 mmHg and DBP=7.7 mmHg for DATASET2. DATASET1 consistently outperforms DATASET2, affirming the algorithm's efficacy during resting states and that estimation during physical activity introduces challenges, requiring further refinement and research for real-world applications. In conclusion, this research unveils a viable solution for continuous cuff-less BP monitoring, while emphasizing the need for refinement and validation to enhance its clinical applicability and accessibility.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-26 at 17:53:34 | Privacy Policy | Personal Data Protection Policy | Whistleblowing