Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Flow-through Dispersed Carbon Nanofiber-Based Microsolid-Phase Extraction Coupled to Liquid Chromatography for Automatic Determination of Trace Levels of Priority Environmental Pollutants
Publication

Publications

Flow-through Dispersed Carbon Nanofiber-Based Microsolid-Phase Extraction Coupled to Liquid Chromatography for Automatic Determination of Trace Levels of Priority Environmental Pollutants

Title
Flow-through Dispersed Carbon Nanofiber-Based Microsolid-Phase Extraction Coupled to Liquid Chromatography for Automatic Determination of Trace Levels of Priority Environmental Pollutants
Type
Article in International Scientific Journal
Year
2011
Authors
Warunya Boonjob
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Manuel Miro
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Marcela A Segundo
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Victor Cerda
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Journal
Title: Analytical ChemistryImported from Authenticus Search for Journal Publications
Vol. 83 No. 13
Pages: 5237-5244
ISSN: 0003-2700
Indexing
Publicação em ISI Web of Science ISI Web of Science
Pubmed / Medline
Scientific classification
FOS: Natural sciences > Chemical sciences
CORDIS: Physical sciences > Chemistry > Analytical chemistry
Other information
Authenticus ID: P-002-Q5H
Resumo (PT): Handling of carbon nanoparticles as sorptive materials in a flow-through packed-bed mode has been to date hampered by undue pressure drop and deteriorated retention efficiency because of nanoparticle bundling and entanglement. To surmount this limitation, a dedicated stirred-flow sorptive microchamber integrated in a fully automated sequential injection (SI) assembly is herein proposed for expedient handling and reuse of carbon nanoparticles in microsolid-phase extraction (μSPE) procedures. The assembled setup features automatic uptake, preconcentration, and retrieval of target organic species using dispersed nanoparticles as a front-end to liquid chromatographic (LC) assays. Chlorotriazine residues (atrazine, simazine, and propazine) and dealkylated metabolites thereof (deisopropyltriazine (DIA) and deethylatrazine (DEA)) were selected as model compounds because of their electron-poor aromatic structure and potentially strong π–π interactions with electron-rich sorptive materials. The effect of several parameters on the analytical performance including the type and amount of nanoparticles (carbon nanofibers (CNFs), multiwalled carbon nanotubes (MWCNTs) and oxidized carbon nanotubes (MWCNT-COOH), the sample volume (breakthrough volume), the nature and volume of eluent, and the interface between the sample processing module and LC was explored in detail. Using dispersed CNFs at-line coupled to LC, absolute recovery percentages for 10 mL sample percolation were >94% for the overall herbicides with enrichment factors of ca. 20, limits of detection (S/N = 3) of 0.004–0.03 ng mL–1, limits of quantification (S/N = 10) of 0.01–0.09 ng mL–1 and repeatability within the range 0.5–1.8%. The SI-CNF-LC hyphenated system was harnessed to the analysis of not merely untreated environmental waters at concentration levels below those endorsed by the current EU Water Framework Directives but to crude soil extracts for which CNF reuse with no loss of retention efficiency was proven feasible by resorting to appropriate automatic regeneration procedures and internal standardization. <br> <br> <a target="_blank" href="http://pubs.acs.org/doi/abs/10.1021/ac2005058"> Texto integral</a> <br> <br>
Abstract (EN): Handling of carbon nanoparticles as sorptive materials in a flow-through packed-bed mode has been to date hampered by undue pressure drop and deteriorated retention efficiency because of nanoparticle bundling and entanglement. To surmount this limitation, a dedicated stirred-flow sorptive microchamber integrated in a fully automated sequential injection (SI) assembly is herein proposed for expedient handling and reuse of carbon nanoparticles in microsolid-phase extraction (mu SPE) procedures. The assembled setup features automatic uptake, preconcentration, and retrieval of target organic species using dispersed nanopartides as a front-end to liquid chromatographic (LC) assays. Chlorotriazine residues (atrazine, simazine, and propazine) and deallcylated metabolites thereof (deisopropyltriazine (DIA) and deethylatrazine (DEA)) were selected as model compounds because of their electron-poor aromatic structure and potentially strong pi-pi interactions with electron-rich sorptive materials. The effect of several parameters on the analytical performance including the type and amount of nanoparticles (carbon nanofibers (CNFs), multiwalled carbon nanotubes (MWCNTs) and oxidized carbon nanotubes (MWCNT-COOH); the sample volume (breakthrough volume), the nature and volume of eluent, and the interface between the sample processing module and LC was explored in detail. Using dispersed CNFs at-line coupled to LC, absolute recovery percentages for 10 mL sample percolation were >94% for the overall herbicides with enrichment factors of ca. 20, limits of detection (S/N = 3) of 0.004-0.03 ng mL(-1), limits of quantification (S/N = 10) of 0.01-0.09 ng mL(-1) and repeatability within the range 0.5-1.8%. The SI-CNF-LC hyphenated system was harnessed to the analysis of not merely untreated environmental waters at concentration levels below those endorsed by the current EU Water Framework Directives but to crude soil extracts for which CNF reuse with no loss of retention efficiency was proven feasible by resorting to appropriate automatic regeneration procedures and internal standardization.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Online Hyphenation of Multimodal Microsolid Phase Extraction Involving Renewable Molecularly Imprinted and Reversed-Phase Sorbents to Liquid Chromatography for Automatic Multiresidue Assays (2010)
Article in International Scientific Journal
Warunya Boonjob; Yongliang L Yu; Manuel Miro; Marcela A Segundo; Jianhua H Wang; Victor Cerda

Of the same scientific areas

Finnee (2016)
Academic Work
Guillaume Erny
glerny/Finnee2016 (2017)
Other Publications
Guillaume Erny
UNLEASHING UNTARGETED HYPHENATED MS ANALYSIS WITH CHEMOMETRICS (2016)
Summary of Presentation in an International Conference
Guillaume Erny; Arminda Alves

See all (23)

Of the same journal

Voltammetric Studies of Topotecan Transfer Across Liquid/Liquid Interfaces and Sensing Applications (2015)
Article in International Scientific Journal
Kim, HR; Carlos M Pereira; Han, HY; Lee, HJ
Unbreakable solid-phase microextraction fibers obtained by sol-gel deposition on titanium wire (2006)
Article in International Scientific Journal
Azenha, MA; Nogueira, PJ; Silva, AF
Subppm Amine Detection via Absorption and Luminescence Turn-On Caused by Ligand Exchange in Metal Organic Frameworks (2019)
Article in International Scientific Journal
Sousaraei, A; Queiros, C; Moscoso, FG; Tania, C; Pedrosa, JM; Silva, AMG; Cunha Silva, L; Cabanillas Gonzalez, J
Recent Advances on Mass Spectrometry Analysis of Nitrated Phospholipids (2016)
Article in International Scientific Journal
Melo, T; Domingues, P; Ferreira, R; Milic, I; Fedorova, M; Santos, SM; Marcela A Segundo; Domingues, MRM

See all (21)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-15 at 16:04:51 | Privacy Policy | Personal Data Protection Policy | Whistleblowing