Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Flow system with electrochemical detection for determination of paracetamol in pharmaceutical preparations
Publication

Publications

Flow system with electrochemical detection for determination of paracetamol in pharmaceutical preparations

Title
Flow system with electrochemical detection for determination of paracetamol in pharmaceutical preparations
Type
Article in International Scientific Journal
Year
2006
Authors
Silva, M.L.S.
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
M. Beatriz Q. Garcia
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 24 No. 2
Pages: 261-271
ISSN: 0872-1904
Scientific classification
FOS: Medical and Health sciences > Other medical sciences
CORDIS: Health sciences
Other information
Resumo (PT): A FIA system with electrochemical detection was developed for the automatic determination of paracetamol in pharmaceutical formulations. The analytical difficulties caused by adsorption of matrix excipients in the electrode surface were surpassed by an on-line electrochemical regeneration of the glassy carbon tubular electrode, using the carrier solution, enabling the renewal of the electrode surface in a simple and rapid way. A single channel FIA manifold was developed, which provided reproducibility of sample transport to the detector and minimized the contact time between samples and electrode surface, thus reducing its cleaning frequency and permitting a high sampling rate to be achieved. Furthermore, the physical characteristics of the electrochemical cell permitted its easy incorporation in the FIA manifold, offering robustness to the system, and allowed it to be generalized to routine analysis applications. With the optimized parameters, a linear correlation between paracetamol concentration and peak current intensity was obtained up to 4 ´ 10-4 mol L-1, with a detection limit of 2.5 ´ 10-5 mol L-1. Paracetamol was quantified in pharmaceutical dosage forms and the results were compared to those obtained for the official spectrophotometric method (BP 1998). Correlation between the results obtained by both methods was linear and no statistical difference between methods was found at the 95% confidence level. <br> <br> Keywords: paracetamol; electrochemical detection; tubular electrodes; flow system. <br> <a target="_blank" href="http://www.scielo.oces.mctes.pt/scielo.php?script=sci_abstract&pid=S0872-19042006000200008&lng=en&nrm=iso&tlng=en "> Texto integral </a> <br> <br>
Abstract (EN): A FIA system with electrochemical detection was developed for the automatic determination of paracetamol in pharmaceutical formulations. The analytical difficulties caused by adsorption of matrix excipients in the electrode surface were surpassed by an on-line electrochemical regeneration of the glassy carbon tubular electrode, using the carrier solution, enabling the renewal of the electrode surface in a simple and rapid way. A single channel FIA manifold was developed, which provided reproducibility of sample transport to the detector and minimized the contact time between samples and electrode surface, thus reducing its cleaning frequency and permitting a high sampling rate to be achieved. Furthermore, the physical characteristics of the electrochemical cell permitted its easy incorporation in the FIA manifold, offering robustness to the system, and allowed it to be generalized to routine analysis applications. With the optimized parameters, a linear correlation between paracetamol concentration and peak current intensity was obtained up to 4 ´ 10-4 mol L-1, with a detection limit of 2.5 ´ 10-5 mol L-1. Paracetamol was quantified in pharmaceutical dosage forms and the results were compared to those obtained for the official spectrophotometric method (BP 1998). Correlation between the results obtained by both methods was linear and no statistical difference between methods was found at the 95% confidence level. <br> <br> Keywords: paracetamol; electrochemical detection; tubular electrodes; flow system. <br> <a target="_blank" href="http://www.scielo.oces.mctes.pt/scielo.php?script=sci_abstract&pid=S0872-19042006000200008&lng=en&nrm=iso&tlng=en "> Full text </a> <br> <br>
Language: Portuguese
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

The influence of Li on the electrochemical behaviour of pure aluminium (1989)
Article in International Scientific Journal
J. C. Fricain; M. A. Travassos; E. Leitão; C. M. Rangel; M. Barbosa; M. G. S. Ferreira
Quantification of Nickel Species in Physiological Media Using Microelectrodes (1995)
Article in International Scientific Journal
M. C. Pereira; J. P. Sousa
O efeito da soldadura na corrosão de um aço macio (1996)
Article in International Scientific Journal
Maria Cristina S. Nunes; Quitéria P. M. Silva; José Inácio F. P. Martins

See all (13)