Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > GC Determination of Acetone, Acetaldehyde, Ethanol, and Methanol in Biological Matrices and Cell Culture
Publication

Publications

GC Determination of Acetone, Acetaldehyde, Ethanol, and Methanol in Biological Matrices and Cell Culture

Title
GC Determination of Acetone, Acetaldehyde, Ethanol, and Methanol in Biological Matrices and Cell Culture
Type
Article in International Scientific Journal
Year
2009
Authors
Pontes, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos A
(Author)
FMUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Fernando Remiao
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Felix Carvalho
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page Without ORCID
Maria de Lourdes Bastos
(Author)
FFUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Journal
Vol. 47 No. 2
Pages: 272-278
ISSN: 0021-9665
Indexing
Scientific classification
FOS: Medical and Health sciences > Other medical sciences
CORDIS: Health sciences
Other information
Authenticus ID: P-003-M5K
Resumo (PT): A gas chromatography with flame ionization detection method (GC–FID) with direct injection, using a capillary column, was validated to determine ethanol, acetaldehyde, methanol, and acetone in different human matrices, such as whole blood, vitreous humour, and urine, with clinical and forensic interest. This method was also employed to quantify these compounds in cell culture medium, thus being useful in basic research. A good peak resolution was achieved, with linear correlation between concentration and peak areas for all the compounds in all the matrices. The inter- and intra-day precisions of the method were always under 15% and 10%, respectively. The accuracy of the method, calculated as the percentage of the target concentration, was within the acceptable limits. The obtained limits of detection were below 0.85 mg/L for acetaldehyde and below 0.75 mg/L for the other considered compounds. The small injection volume and the high split ratios applied, allied to the high performance of the GC column, resulted in very good peak resolution and high sensitivities. This method is easy to perform, making it suitable for the routine of clinical biochemistry and forensic laboratories. <br> <br>
Abstract (EN): A gas chromatography with flame ionization detection method (GC-FID) with direct injection, using a capillary column, was validated to determine ethanol, acetaldehyde, methanol, and acetone in different human matrices, such as whole blood, vitreous humour, and urine, with clinical and forensic interest. This method was also employed to quantify these compounds in cell culture medium, thus being useful in basic research. A good peak resolution was achieved, with linear correlation between concentration and peak areas for all the compounds in all the matrices. The inter- and intra-day precisions of the method were always under 15% and 10%, respectively. The accuracy of the method, calculated as the percentage of the target concentration, was within the acceptable limits. The obtained limits of detection were below 0.85 mg/L for acetaldehyde and below 0.75 mg/L for the other considered compounds. The small injection volume and the high split ratios applied, allied to the high performance of the GC column, resulted in very good peak resolution and high sensitivities. This method is easy to perform, making it suitable for the routine of clinical biochemistry and forensic laboratories.
Language: English
Type (Professor's evaluation): Scientific
Contact: pguedes@ff.up.pt
No. of pages: 7
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same journal

Uncertainty Measurement of Chlorophenols and PCBs Analyzed in Aqueous Media by SPME-GC-ECD (2009)
Article in International Scientific Journal
Silva, SL; Alves, A; Santos, L
Uncertainty measurement of chlorophenols and PCBs analysis in aqueous media by SPME-GC-ECD (2009)
Article in International Scientific Journal
Sofia Silva; A. Alves; L. Santos
GC Determination of Acetone, Acetaldehyde, Ethanol, and Methanol in Biological Matrices and Cell Culture (2009)
Article in International Scientific Journal
Helena Pontes; de Pinho, PG; Susana Casal; Helena Carmo; Agostinho Santos; Teresa Magalhaes; Fernando Remiao; Felix Carvalho; Maria Lourdes Bastos
Development of an Analytical Methodology for Simultaneous Determination of Vincristine and Doxorubicin in Pharmaceutical Preparations for Oncology by HPLC-UV (2009)
Article in International Scientific Journal
Rodrigues, AS; Lopes, AR; Leao, A; Couceiro, A; Sarmento Ribeiro, ABS; Ramos, F; Noronha da Silveira, MIN; de Oliveira, CR
Development and validation of an HPLC method for the quantitation of 1,3-dihydroxy-2-methylxanthone in biodegradable nanoparticles (2008)
Article in International Scientific Journal
Teixeira, M; Carlos Afonso; Madalena Pinto; Barbosa, C.M.

See all (9)

Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-14 at 16:33:44 | Privacy Policy | Personal Data Protection Policy | Whistleblowing