Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > RPC-PET: a new very high resolution PET technology
Publication

Publications

RPC-PET: a new very high resolution PET technology

Title
RPC-PET: a new very high resolution PET technology
Type
Article in International Conference Proceedings Book
Year
2004
Authors
Blanco, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Carolino, N
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Ferreira, NC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Correia, CMBA
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Macedo, MP
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Fazendeiro, L
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Marques, MFF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Marques, RF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Gil, C
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Fonte, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Conference proceedings International
Pages: 2356-2360
Nuclear Science Symposium/Medical Imaging Conference
Rome, ITALY, OCT 16-22, 2004
Other information
Authenticus ID: P-008-R01
Abstract (EN): In this study we present experimental and simulated results from a first prototype of a positron emission tomography (PET) system based on the resistive plate chamber (RPC) technology - a gaseous particle detector developed for high energy physics. The prototype is aimed at validating the expectations, derived from simulations, of a system with sub-millimeter spatial image resolution and no parallax error, which may be useful for the imaging of small animals. By imaging a point-like 22Na source in the transaxial plane, an intrinsic spatial resolution of 0.52 mm FWHM was demonstrated for a system diameter of 60 mm. A corresponding image spatial resolution of 0.5 mm FWHM was obtained using the standard algorithm of filtered back projection and 0.4 mm FWHM after reconstruction by an ML-EM type algorithm. An optimized complete system was simulated to evaluate sensitivity and system count rate performance for the imaging of mice, suggesting a sensitivity up to 2.1 % at the centre of the field of view and a peak NEC rate up to 320 Kcps for a total activity of 100MBq in the phantom. © 2004 IEEE.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 5
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Very high position resolution gamma imaging with resistive plate chambers (2006)
Article in International Scientific Journal
Blanco, A; Carolino, N; Correia, CMBA; Fazendeiro, L; Ferreira, NC; Marques, MFF; Marques, RF; Fonte, P; Gil, C; Macedo, MP
Spatial resolution on a small animal RPC-PET prototype operating under magnetic field (2006)
Article in International Scientific Journal
Blanco, A; Carolino, N; Correia, CMBA; Fazendeiro, L; Ferreira, NC; Marques, MFF; Marques, RF; Fonte, P; Gil, C; Macedo, MP
RPC-PET: A new very high resolution PET technology (2006)
Article in International Scientific Journal
Blanco, A; Carolino, N; Correia, CMBA; Fazendeiro, L; Ferreira, NC; Marques, MFF; Marques, RF; Fonte, P; Gil, C; Macedo, MP
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-23 at 07:12:03 | Privacy Policy | Personal Data Protection Policy | Whistleblowing