High speed multi input VME acquisition system

Title
High speed multi input VME acquisition system
Type
Article in International Conference Proceedings Book
Year
1996
Authors
Loureiro, CFM
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Combo, AMCF
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Simoes, JB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Correia, CMBA
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Silva, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Conference proceedings International
Pages: 487-489
Proceedings of the 1996 IEEE Nuclear Science Symposium. Part 1 (of 3)
Anaheim, CA, USA, 2 November 1996 through 9 November 1996
Indexing
Publicação em Scopus Scopus - 0 Citations
Other information
Authenticus ID: P-007-74J
Abstract (EN): An implementation of an architecture designed to lower the problems associated with finite data acquisition memories and relatively high undesired dead times, usually found in high energy experiments, is presented. The architecture allows up to four similar data acquisition channels, capable of acquiring continuously up to 3 Mbytes of data at a 250 MHz sampling rate, to be housed in a single width double height VME bus module. Provision is made to operate the channels in an interleaved way, achieving higher sampling rates. The module will be the basis of an upgrade of the dedicated data acquisition system for the reflectometry diagnostic on the Asdex-Upgrade tokamak.
Language: English
Type (Professor's evaluation): Scientific
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-14 at 00:23:29 | Privacy Policy | Personal Data Protection Policy | Whistleblowing