Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > New optical probe approach using mixing effect in planar photodiode for biomedical applications
Publication

Publications

New optical probe approach using mixing effect in planar photodiode for biomedical applications

Title
New optical probe approach using mixing effect in planar photodiode for biomedical applications
Type
Article in International Conference Proceedings Book
Year
2013
Authors
Pereira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Vaz, P
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Oliveira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Santos, I
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Leal, A
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Almeida, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Pereira, H
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Correia, C
(Author)
FCUP
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Cardoso, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Conference proceedings International
Conference on Optical Sensors
Prague, CZECH REPUBLIC, APR 15-17, 2013
Indexing
Other information
Authenticus ID: P-006-FWM
Abstract (EN): The laser diode self-mixing technique is a well-known and powerful interferometric technique that has been used in biomedical applications, namely for the extraction of cardiovascular parameters. However, to construct an optical probe using the self-mixing principle which is able to acquire signals in the human carotid artery, some problems are expected. The laser diode has a small aperture area, which means that, for physiological sensing purposes, it can be considered as a point-like detector. This feature imparts difficulties to quality recording of physiological signals since the number of photons collected and mixed in the cavity of the photodiode is very small. In order to overcome this problem, a new mixing geometry based on an external large area planar photodiode (PD) is used in the probe, enabling a much larger number of photons to be collected, hence improving the quality of the signal. In this work, the possibility to obtain the mixing effect outside the laser cavity using an external photodetector, such as a planar photodiode, is demonstrated. Two test benches were designed, both with of two reflectors. The first one, which reflects the light beam with the same frequency of the original one is fixed, and the second one, is movable, reflecting the Doppler shifted light to the photodetector. The first test bench has a fixed mirror in front of the movable mirror, creating an umbra and penumbra shadow above the movable mirror. To avoid this problem, another test bench was constructed using a wedged beam splitter (WSB) instead of a fixed mirror. This new assembly ensures the separation of a single input beam into multiple copies that undergo successive reflections and refractions. Some light waves are reflected by the planar surface of WSB, while other light beams are transmitted through the WSB, reaching the movable mirror. Also in this case, the movable mirror reflects the light with a Doppler frequency shift, and the PD receives both beams. The two test benches were designed to demonstrate that it is possible to obtain mixing effect outside the laser cavity, using a planar photodiode. The Doppler spectrograms from the signals acquired in the test benches show that the signal frequency changes along time which correspond to the modulus of the derivative of the mirror movement, as expected in the self-mixing signals. Nevertheless, the test bench A showed better results than the test bench B. This fact probably results from the attenuation that the original beam suffers in each reflection and refraction in the WBS. Tests developed in the test benches opened the possibility to construct a probe that uses a planar photodiode with a large area to collect medical signals, and improve the quality of the acquisition with a better SNR.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 8
Documents
We could not find any documents associated to the publication.
Related Publications

Of the same authors

Characterization of Optical System for Hemodynamic Multi-Parameter Assessment (2013)
Article in International Scientific Journal
Pereira, T; Santos, I; Oliveira, T; Vaz, P; Correia, T; Pereira, T; Santos, H; Pereira, H; Almeida, V; Cardoso, J; Correia, C
Local PWV and other hemodynamic parameters assessment: Validation of a new optical technique in an healthy population (2013)
Article in International Conference Proceedings Book
Pereira, T; Santos, I; Oliveira, T; Vaz, P; Pereira, T; Santos, H; Pereira, H; Almeida, V; Cardoso, J; Correia, C
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-06 at 23:57:16 | Privacy Policy | Personal Data Protection Policy | Whistleblowing