Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > Visible and Infrared Optical Probes for Hemodynamic Parameters Assessment
Publication

Publications

Visible and Infrared Optical Probes for Hemodynamic Parameters Assessment

Title
Visible and Infrared Optical Probes for Hemodynamic Parameters Assessment
Type
Article in International Conference Proceedings Book
Year
2011
Authors
Pereira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Oliveira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Cabeleira, M
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Almeida, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Borges, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Cardoso, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Correia, C
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Pereira, HC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Conference proceedings International
Pages: 1796-1799
10th IEEE Conference on Sensors
Limerick, IRELAND, OCT 28-31, 2011
Other information
Authenticus ID: P-002-WYD
Abstract (EN): Four optical probes were developed to measure the arterial distension waveform generated by the ventricular contraction and assess clinically relevant information. The pressure wave propagates through the arterial tree and can be measured in the peripheral arteries. The probes make use of two distinct photo-detectors: planar and avalanche photodiodes. Independently, two different light sources were tested: visible and infrared light. Performance of the probes was evaluated in a test setup that simulates the fatty deposits commonly seen in the obese, between skin and the artery. The probes show good overall performance in the test setup with less than 8% root mean square error (RMSE). However, the probes lit with IR sources show better results for the more extreme cases, with a better resolution in the waveform, higher definition of notable points and higher SNR when compared to the visible source signals. In vivo, the IR probes allow easier waveform detection, even more relevant with the increasing of the deposit structures.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-07-21 at 01:06:31 | Privacy Policy | Personal Data Protection Policy | Whistleblowing