Go to:
Logótipo
Comuta visibilidade da coluna esquerda
Você está em: Start > Publications > View > DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION A New Device for Hemodynamic Parameters Assessment
Publication

Publications

DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION A New Device for Hemodynamic Parameters Assessment

Title
DOUBLE HEADED PROBE FOR LOCAL PULSE WAVE VELOCITY ESTIMATION A New Device for Hemodynamic Parameters Assessment
Type
Article in International Conference Proceedings Book
Year
2011
Authors
Pereira, HC
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Simoes, JB
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Malaquias, JL
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Pereira, T
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Almeida, V
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Borges, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Figueiras, E
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. Without AUTHENTICUS Without ORCID
Cardoso, J
(Author)
Other
The person does not belong to the institution. The person does not belong to the institution. The person does not belong to the institution. View Authenticus page Without ORCID
Correia, C
(Author)
Other
View Personal Page You do not have permissions to view the institutional email. Search for Participant Publications View Authenticus page View ORCID page
Conference proceedings International
Pages: 444-447
International Conference on Biomedical Electronics and Devices, BIODEVICES 2011
Rome, 26 January 2011 through 29 January 2011
Other information
Authenticus ID: P-002-W3C
Abstract (EN): The present work proposes a new device for local pulse wave velocity (PWV), by using an innovative configuration of a double piezoelectric (PZ) sensor probe. PWV is assessed in one single location and involves the determination of time delay, between the signals acquired simultaneously by two PZs, 23 mm apart. The double probe (DP) is characterized in a dedicated test bench system, where two main studies were carried out. In the first one, the impulse response (IR) for each PZ sensor is determined and evaluated through the deconvolution method. In the second one, DP time resolution is estimated from a set of time delay algorithms and compared with the reference values, obtained through the signals of two pressure sensors. Results demonstrate the effectiveness of the inferred IRs in deconvolution purposes and the possibility of measure higher PWV values (approximate to 19m/s), through the DP, with an error less than 10%.
Language: English
Type (Professor's evaluation): Scientific
No. of pages: 4
Documents
We could not find any documents associated to the publication.
Recommend this page Top
Copyright 1996-2025 © Faculdade de Direito da Universidade do Porto  I Terms and Conditions  I Acessibility  I Index A-Z
Page created on: 2025-08-07 at 02:59:26 | Privacy Policy | Personal Data Protection Policy | Whistleblowing